Repeatability of B1 + inhomogeneity correction of volumetric (3D) glutamate CEST via High-permittivity dielectric padding at 7T.
Jacobs, Paul S; Benyard, Blake; Cember, Abigail; Nanga, Ravi Prakash Reddy; Cao, Quy; Tisdall, M Dylan; Wilson, Neil; Das, Sandhitsu; Davis, Kathryn A; Detre, John; Roalf, David; Reddy, Ravinder.
Afiliación
  • Jacobs PS; Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Benyard B; Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Cember A; Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Nanga RPR; Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Cao Q; Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Tisdall MD; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Wilson N; Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Das S; Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Davis KA; Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Detre J; Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Roalf D; Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Reddy R; Department of Psychiatry, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Magn Reson Med ; 88(6): 2475-2484, 2022 Dec.
Article en En | MEDLINE | ID: mdl-36178233
ABSTRACT

PURPOSE:

Ultra-high field MR imaging lacks B1 + inhomogeneity due to shorter RF wavelengths used at higher field strengths compared to human anatomy. CEST techniques tend to be highly susceptible to B1 + inhomogeneities due to a high and uniform B1 + field being necessary to create the endogenous contrast. High-permittivity dielectric pads have seen increasing usage in MR imaging due to their ability to tailor the spatial distribution of the B1 + field produced. The purpose of this work is to demonstrate that dielectric materials can be used to improve glutamate weighted CEST (gluCEST) at 7T. THEORY AND

METHODS:

GluCEST images were acquired on a 7T system on six healthy volunteers. Aqueous calcium titanate pads, with a permittivity of approximately 110, were placed on either side in the subject's head near the temporal lobes. A post-processing correction algorithm was implemented in combination with dielectric padding to compare contrast improvement. Tissue segmentation was performed to assess the effect of dielectric pads on gray and white matter separately.

RESULTS:

GluCEST images demonstrated contrast enhancement in the lateral temporal lobe regions with dielectric pad placement. Tissue segmentation analysis showed an increase in correction effectiveness within the gray matter tissue compared to white matter tissue. Statistical testing suggested a significant difference in gluCEST contrast when pads were used and showed a difference in the gray matter tissue segment.

CONCLUSION:

The use of dielectric pads improved the B1 + field homogeneity and enhanced gluCEST contrast for all subjects when compared to data that did not incorporate padding.