Your browser doesn't support javascript.
loading
First-in-human evaluation of an independently developed Chinese robot-assisted system for percutaneous coronary intervention.
Zhai, Guang-Yao; Chen, Zheng; Liu, Rui-Fang; Guo, Yong-He; Wang, Jian-Long; Sun, Tie-Nan; Xie, Jing; Huang, Tao; Zhou, Yu-Jie.
Afiliación
  • Zhai GY; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing Key Laboratory of Precision Medicine of Coronary Atherosclerotic Disease, Clinical Center for Coronary Heart Disease, Capital Medical University, Beijing,
  • Chen Z; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing Key Laboratory of Precision Medicine of Coronary Atherosclerotic Disease, Clinical Center for Coronary Heart Disease, Capital Medical University, Beijing,
  • Liu RF; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing Key Laboratory of Precision Medicine of Coronary Atherosclerotic Disease, Clinical Center for Coronary Heart Disease, Capital Medical University, Beijing,
  • Guo YH; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing Key Laboratory of Precision Medicine of Coronary Atherosclerotic Disease, Clinical Center for Coronary Heart Disease, Capital Medical University, Beijing,
  • Wang JL; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing Key Laboratory of Precision Medicine of Coronary Atherosclerotic Disease, Clinical Center for Coronary Heart Disease, Capital Medical University, Beijing,
  • Sun TN; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing Key Laboratory of Precision Medicine of Coronary Atherosclerotic Disease, Clinical Center for Coronary Heart Disease, Capital Medical University, Beijing,
  • Xie J; Beijing WeMed Medical Equipment Co., Ltd., Beijing, China.
  • Huang T; Beijing WeMed Medical Equipment Co., Ltd., Beijing, China.
  • Zhou YJ; Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart Lung and Blood Vessel Disease, Beijing Key Laboratory of Precision Medicine of Coronary Atherosclerotic Disease, Clinical Center for Coronary Heart Disease, Capital Medical University, Beijing,
J Geriatr Cardiol ; 19(10): 743-752, 2022 Oct 28.
Article en En | MEDLINE | ID: mdl-36338278
ABSTRACT

BACKGROUND:

Several studies have proved the safety and feasibility of robot-assisted percutaneous coronary intervention (PCI) in reducing the occupational hazards of interventionists while achieving precision medicine. However, an independently developed robot-assisted system for PCI in China has not yet emerged. This study aimed to evaluate the safety and feasibility of a robot-assisted system for elective PCI in China.

METHODS:

This preclinical trial included 22 experimental pigs and preliminarily supported the safety and feasibility of the ETcath200 robot-assisted system for PCI. Then, eleven patients with coronary heart disease who met the inclusion criteria and had clinical indications for elective PCI were enrolled. PCI was performed using a robot-assisted system. The primary outcomes were clinical success (defined as visual estimated residual stenosis < 30% after PCI and no major adverse cardiovascular events during hospitalization and within 30 days after PCI) and technical success (defined as the ability to use the robot-assisted system to complete PCI successfully without conversion to the traditional manual PCI).

RESULTS:

Eleven patients were included in this clinical trial. A drug-eluting stent with a diameter of 3 mm (interquartile range 2.75-3.5 mm) and a length of 26 mm (interquartile range 22-28 mm) was deployed in all patients. The clinical success rate was 100%, with no PCI-related complications and no in-hospital or 30-day major adverse cardiovascular events, and the technical success rate was 100%.

CONCLUSIONS:

The results strongly suggest that the use of the independently developed robot-assisted system in China for elective PCI is feasible, safe, and effective.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: J Geriatr Cardiol Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: J Geriatr Cardiol Año: 2022 Tipo del documento: Article
...