Your browser doesn't support javascript.
loading
Evaluation of the ESR fast detector and Improve® ESR analyzer as modified Westergren methods for erythrocyte sedimentation rate.
Chomean, Sirinart; Thamwarokun, Areenuch; Jitsuvantaya, Sumittra; Attapong, Jirapat; Kaset, Chollanot.
Afiliación
  • Chomean S; Department of Medical Technology, Faculty of Allied Health Sciences, Thammasat University, Pathumtani, Thailand.
  • Thamwarokun A; Thammasat University Research Unit in Medical Technology and Precision Medicine Innovation.
  • Jitsuvantaya S; Graduate Program in Biomedical Sciences, Faculty of Allied Health Sciences, Thammasat University, Pathumtani, Thailand.
  • Attapong J; Graduate Program in Biomedical Sciences, Faculty of Allied Health Sciences, Thammasat University, Pathumtani, Thailand.
  • Kaset C; Graduate Program in Biomedical Sciences, Faculty of Allied Health Sciences, Thammasat University, Pathumtani, Thailand.
Scand J Clin Lab Invest ; 82(7-8): 581-587, 2022.
Article en En | MEDLINE | ID: mdl-36372996
ABSTRACT
The erythrocyte sedimentation rate (ESR) has been commonly ordered in hematology laboratories and used to screen for monitoring responses to therapy and identifying inflammatory conditions. To overcome the limitations of traditional ESR measurements, various methods have been developed and compared to the established reference method. This study evaluates the analytical performance of ESR fast detector and Improve® ESR analyzer compared to the reference method. Method validation and comparison were performed in 189 volunteer blood samples according to the International Council for Standardization in Hematology recommendations. The analytical efficacy of ESR fast detector and Improve® ESR analyzer was also assessed and compared with the reference method and C-reactive protein (CRP) levels. The results demonstrated that the precision of ESR fast detector and Improve® ESR analyzer was considered as the acceptance criterion for the ESR measurement. The method comparison analysis between the two modified Westergren methods and reference method demonstrated a strong correlation with the Spearman's rank correlation coefficient of 0.94, with a mean difference of -2.1 and -7.7 mm/h in the ESR fast detector and Improve® ESR analyzer, respectively. Analysis of the area under the receiver operating curve illustrated a high analytical performance compared to the reference method and CRP level. The measurement of ESR level using the ESR fast detector and Improve® ESR analyzer is a reliable method and has a high analytical performance, which can be used instead of the reference method for screening inflammatory conditions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hematología Tipo de estudio: Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: Scand J Clin Lab Invest Año: 2022 Tipo del documento: Article País de afiliación: Tailandia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hematología Tipo de estudio: Guideline / Prognostic_studies Límite: Humans Idioma: En Revista: Scand J Clin Lab Invest Año: 2022 Tipo del documento: Article País de afiliación: Tailandia
...