Your browser doesn't support javascript.
loading
Cross-cultural adaptation of the Taiwan Chinese version of the Falls Efficacy Scale-International for community-dwelling elderly individuals.
Chang, Kai-Chieh; Chen, Hsin-Shui; Horng, Yi-Shiung; Liou, Horng-Hui; Liang, Huey-Wen.
Afiliación
  • Chang KC; Department of Neurology, National Taiwan University Hospital Yunlin Branch, Yunlin, Taiwan, ROC.
  • Chen HS; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan, ROC.
  • Horng YS; Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital Yunlin Branch, Yunlin, Taiwan, ROC.
  • Liou HH; Department of Physical Medicine and Rehabilitation, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, New Taipei City, Taiwan, ROC.
  • Liang HW; Department of Medicine, Tzu Chi University, Hualien, Taiwan, ROC.
BMC Geriatr ; 22(1): 881, 2022 11 19.
Article en En | MEDLINE | ID: mdl-36402948
BACKGROUND: The Falls Efficacy Scale-International (FES-I) is a commonly used questionnaire to evaluate concerns about falling. We adapted a Taiwan Chinese version (FES-ITC) and evaluated its reliability and validity in community-dwelling elderly individuals. The discriminative validity was tested in relation to several known risk factors for fear of falling (FOF). METHODS: The questionnaire was adapted through translation, back-translation, and expert review processes. A convenience sample of 135 community-dwelling elderly individuals (at least 60 years old) completed the adapted questionnaire, and 31 of them had a retest within 7-10 days. Cronbach's α and an intraclass correlation coefficient (ICC) were used to evaluate the internal consistency and test-retest reliability. Principal component factor analysis was performed to assess the factor-construct validity. The discriminative validity was tested in relation to demographic features, fall-related history and performances on three functional tests: timed up and go, four-stage balance and 30-s chair stand tests. Effect sizes were computed. Correlation coefficients between physical functional performance and FES-ITC scores were computed. Receiver operating characteristic curves were used to determine the cutoff point for the score to differentiate high and low concern of falling. RESULTS: The FES-ITC questionnaire had high internal consistency (Cronbach's α = 0.94) and excellent test-retest reliability (ICC = 0.94). Principal component factor analysis yielded a two-factor model, with several items requiring high demand on postural control loading on factor 2. FES-ITC scores discriminated individuals with different ages, reporting FOF, reporting falls in the past year and using walking aids. However, FES-ITC scores did not differ between the participants who were at risk of falling and those who were not at risk based on functional test performance and there was no correlation found between them. CONCLUSION: The FES-ITC was highly reliable and had adequate construct and discriminative validity. The lack of correlation between FES-ITC scores and functional test performance implied the presence of FOF even in individuals with good functional performance. Further follow up studies are warranted to verify the predictive validity of the FES-ITC.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Accidentes por Caídas / Vida Independiente Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Humans País/Región como asunto: Asia Idioma: En Revista: BMC Geriatr Asunto de la revista: GERIATRIA Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Accidentes por Caídas / Vida Independiente Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Humans País/Región como asunto: Asia Idioma: En Revista: BMC Geriatr Asunto de la revista: GERIATRIA Año: 2022 Tipo del documento: Article
...