Your browser doesn't support javascript.
loading
Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report.
Garzone, Davide; Terheyden, Jan Henrik; Morelle, Olivier; Wintergerst, Maximilian W M; Saßmannshausen, Marlene; Schmitz-Valckenberg, Steffen; Pfau, Maximilian; Thiele, Sarah; Poor, Stephen; Leal, Sergio; Holz, Frank G; Finger, Robert P.
Afiliación
  • Garzone D; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Terheyden JH; Population Health Sciences, German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.
  • Morelle O; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Wintergerst MWM; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Saßmannshausen M; B-IT and Institute of Informatics, University of Bonn, Bonn, Germany.
  • Schmitz-Valckenberg S; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Pfau M; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Thiele S; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Poor S; John A. Moran Eye Center, University of Utah, Salt Lake City, USA.
  • Leal S; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Holz FG; Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe Str. 2, 53127, Bonn, Germany.
  • Finger RP; Ophthalmology, Novartis Institutes for Biomedical Research, Cambridge, MA, USA.
Sci Rep ; 12(1): 21911, 2022 12 19.
Article en En | MEDLINE | ID: mdl-36535990
ABSTRACT
Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991-0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757-0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD.Trial registration ClinicalTrials.gov NCT03349801. Registered on 22 November 2017.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Degeneración Macular Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Degeneración Macular Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Sci Rep Año: 2022 Tipo del documento: Article País de afiliación: Alemania
...