Your browser doesn't support javascript.
loading
Enzyme-linked immunosorbent assay using thin-layered microfluidics with perfect capture of the target protein.
Smirnova, Adelina; Ohta, Ryoichi; Mori, Emi; Shimizu, Hisashi; Morikawa, Kyojiro; Kitamori, Takehiko.
Afiliación
  • Smirnova A; Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan. kitamori@icl.t.u-tokyo.ac.jp.
  • Ohta R; Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan. kitamori@icl.t.u-tokyo.ac.jp.
  • Mori E; Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
  • Shimizu H; Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan. kitamori@icl.t.u-tokyo.ac.jp.
  • Morikawa K; Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan. kitamori@icl.t.u-tokyo.ac.jp.
  • Kitamori T; Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan, Republic of China.
Anal Methods ; 15(5): 675-684, 2023 02 02.
Article en En | MEDLINE | ID: mdl-36655604
ABSTRACT
We developed a process for enzyme-linked immunosorbent assay on a glass microchip via the use of a thin-layered microfluidic channel. This channel possesses a high aspect ratio (width/depth ∼200) and has an antibody layer immobilized directly on the channel surface. A depth of several microns and an excessive width and length (mm scale) of the channel provide a large-volume capacity (102 nL) and maximum capture efficiency of the analyte for a high level of detection sensitivity (102 pg mL-1). The developed reusable immunosensor has demonstrated high-performance characteristics by requiring less than 50 µL of sample and providing analysis in less than 25 min. This new method could impact the development of point-of-care devices for biomedical applications.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Microfluídica Idioma: En Revista: Anal Methods Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Microfluídica Idioma: En Revista: Anal Methods Año: 2023 Tipo del documento: Article País de afiliación: Japón
...