[Coupling capillary electrophoresis-electrospray ionization mass spectrometry with sheathless interface for drug analysis].
Se Pu
; 41(2): 160-167, 2023 Feb.
Article
en Zh
| MEDLINE
| ID: mdl-36725712
Capillary electrophoresis-mass spectrometry ï¼CE-MSï¼ combines the advantages of capillary electrophoresisï¼ such as the high separation efficiency and low sample consumptionï¼ and the high detection sensitivity of mass spectrometry and the ability for providing the structural information for structure elucidation of unknown components. Howeverï¼ the interface technology for coupling capillary electrophoresis and mass spectrometry is still not well resolved. In the present workï¼ we explored the application of the sheathless CE-MS interface which was prepared by gold foil-wrapped CE separation column tip directly as a spray electrode for the analysis of five tyrosine kinase inhibitorsï¼ namely sunitinibï¼ imatinib mesylateï¼ gefitinibï¼ dasatinib and erlotinib. This interface integrates separation and electrospray ionization in one capillaryï¼ which is easy to manufactureï¼ low in costï¼ and can be produced in batches. We found that using the nonaqueous CE separation mode can not only achieve baseline separation of five tyrosine kinase inhibitorsï¼ but also obtain stable mass spectrometry signals. Firstï¼ we investigated the effect of the electrolyte solution composition on the separation. The optimized background electrolyte composition was obtainedï¼ 2% ï¼v/vï¼ acetic acid and 5 mmol/L ammonium acetate in acetonitrile-methanol ï¼80â¶20ï¼ v/vï¼. Under optimized conditionsï¼ the five kinase inhibitors could be baseline separatedï¼ meantimeï¼ the sheathless interface could also maintain stable electrospray for a long time. The relative standard deviation ï¼RSDï¼ values of the intraday and interday repeatability of the analyte retention times were less than 0.5% and 0.8%ï¼ respectivelyï¼ and the RSD value between interface batches is less than 2.6%. Compared with CE-MS with aqueous phaseï¼ the separation column efficiency of the five tyrosine kinase inhibitors under nonaqueous phase conditions is higherï¼ the detection sensitivity is higherï¼ and the absolute detection limit reaches amol level. In additionï¼ we evaluated the sheathless interface with various organic acidsï¼ such as palaflin Aï¼ salvianolic acid Cï¼ and rosmarinic acidï¼ as well as hydrophobic macrolide antibioticsï¼ azithromycinï¼ erythromycinï¼ and sporin Aï¼ good separation effect and mass spectrometric detection results can be obtained.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Agua
/
Espectrometría de Masa por Ionización de Electrospray
Idioma:
Zh
Revista:
Se Pu
Año:
2023
Tipo del documento:
Article