Your browser doesn't support javascript.
loading
Evaluation of a Viscoelastic Coagulation Monitoring System (VCM Vet®) and Its Correlation with Thromboelastometry (ROTEM®) in Diseased and Healthy Dogs.
Hennink, Imke; Peters, Laureen; van Geest, Geert; Adamik, Katja-Nicole.
Afiliación
  • Hennink I; Department of Veterinary Clinical Medicine, Division of Small Animal Emergency and Critical Care, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland.
  • Peters L; Department of Veterinary Clinical Medicine, Clinical Laboratory, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland.
  • van Geest G; Interfaculty Bioinformatics Unit, University of Bern, 3012 Bern, Switzerland.
  • Adamik KN; Department of Veterinary Clinical Medicine, Division of Small Animal Emergency and Critical Care, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland.
Animals (Basel) ; 13(3)2023 Jan 25.
Article en En | MEDLINE | ID: mdl-36766294
Thromboelastometry provides a real-time assessment of global coagulation in whole blood. A novel bed-side viscoelastic coagulation monitor (VCM) has been developed for use in small animals. The aims of the study were to determine inter-device agreement of two VCM devices, to evaluate the correlation between VCM and rotational thromboelastometry as a reference method (ROTEM), and to determine the sensitivity and specificity of VCM to diagnose hypo-, normo-, and hypercoagulability. ROTEM (extrinsic and intrinsic activation) analysis was performed using citrated blood and VCM analysis using native blood. Twenty healthy and forty diseased dogs with and without coagulopathies were enrolled. The VCM inter-device agreement was moderate to strong for most of the parameters, depending on the grading scale. Correlation between VCM and ROTEM was moderate to strong for parameters of clotting time and clot strength. The VCM most likely detects true hypocoagulability and reliably rules out hypocoagulability. The VCM has a high sensitivity in diagnosing normocoagulability, but incorrectly classified dogs with abnormal coagulation as normocoagulable. The VCM was not able to detect hypercoagulability. ROTEM and VCM cannot be used interchangeably.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Animals (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Animals (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Suiza
...