Your browser doesn't support javascript.
loading
Comparison of a viscoelastic point-of-care coagulation monitor with thromboelastography in sick dogs with hemostatic abnormalities.
Buriko, Yekaterina; Chalifoux, Nolan V; Clarkin-Breslin, Rachel; Silverstein, Deborah C.
Afiliación
  • Buriko Y; Department of Clinical Sciences and Advanced Medicine, Veterinary Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Chalifoux NV; Department of Clinical Sciences and Advanced Medicine, Veterinary Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Clarkin-Breslin R; Department of Clinical Sciences and Advanced Medicine, Veterinary Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Silverstein DC; Department of Clinical Sciences and Advanced Medicine, Veterinary Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Vet Clin Pathol ; 52(2): 217-227, 2023 Jun.
Article en En | MEDLINE | ID: mdl-36798021
ABSTRACT

BACKGROUND:

Viscoelastic coagulation monitor (VCM-Vet) is a point-of-care device that has been used to characterize hemostatic abnormalities in sick pets but has not been validated in veterinary patients.

OBJECTIVES:

We aimed to compare VCM-Vet and thromboelastography (TEG) in sick dogs with suspected disorders of hemostasis.

METHODS:

Duplicate VCM-Vet tests using untreated native blood performed concurrently on two VCM-Vet machines, and simultaneous TEG tests were performed (one citrated native (CN), and one activated with tissue factor (TF) at a 13600 dilution). Each VCM-Vet result was compared with both TF-activated and CN TEG.

RESULTS:

Fifty-three dogs were enrolled. Eleven cases displayed apparent hyperfibrinolysis. Spearman correlation coefficients for individual VCM-Vet devices and CN and TF TEG were obtained between R and CT values and ranged from 0.21 to 0.27, CFT and K (r = 0.60-0.67), angles (r = 0.51-0.62), and MCF and MA (r = 0.85-0.87). Comparison of the two VCM-Vet devices displayed positive correlations for all clot formation parameters with Lin's concordance correlation coefficients of 0.75-0.95. Variable lysis parameter agreement existed between the VCM-Vet devices and VCM-Vet and TEG. When samples were classified as hypercoagulable or coagulopathic, VCM-Vet had a low positive predictive value (17-33%) for the detection of hypercoagulable states and a moderate negative predictive value (64-74%) for the detection of coagulopathy as defined by TEG.

CONCLUSIONS:

VCM-Vet and TEG had variable correlations in clot formation values and a strong correlation for final clot strength. More information is needed to make conclusions about the lysis parameters. Artifact in the fibrinolysis portion of the test can confound the interpretation of VCM-Vet results.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trastornos de la Coagulación Sanguínea / Hemostáticos / Enfermedades de los Perros Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Vet Clin Pathol Asunto de la revista: MEDICINA VETERINARIA / PATOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trastornos de la Coagulación Sanguínea / Hemostáticos / Enfermedades de los Perros Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Vet Clin Pathol Asunto de la revista: MEDICINA VETERINARIA / PATOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos
...