Improved Brain Tumor Conspicuity at 3 T Using Dark Blood, Fat-Suppressed, Dixon Unbalanced T1 Relaxation-Enhanced Steady-State MRI.
Edelman, Robert R; Walker, Matthew; Ankenbrandt, William J; Leloudas, Nondas; Pang, Jianing; Bailes, Julian; Bobustuc, George; Koktzoglou, Ioannis.
Afiliación
  • Leloudas N; From the Department of Radiology, NorthShore University HealthSystem, Evanston.
  • Pang J; Siemens Medical Solutions USA Inc, Chicago.
  • Bailes J; Departments of Neurosurgery.
  • Bobustuc G; Neurology, NorthShore University HealthSystem, Evanston, IL.
Invest Radiol ; 58(9): 641-648, 2023 09 01.
Article en En | MEDLINE | ID: mdl-36822675
ABSTRACT

OBJECTIVES:

Contrast-enhanced magnetic resonance imaging (MRI) is the cornerstone for brain tumor diagnosis and treatment planning. We have developed a novel dual-echo volumetric dark blood pulse sequence called Dixon unbalanced T1 relaxation-enhanced steady-state (uT 1 RESS) that improves the visibility of contrast-enhancing lesions while suppressing the tissue signals from blood vessels and fat. The purpose of this study was to test the hypothesis that Dixon uT 1 RESS would significantly improve the conspicuity of brain tumors compared with magnetization-prepared rapid gradient echo (MPRAGE), as well as to determine potential limitations of the technique. MATERIALS AND

METHODS:

This retrospective study was approved by the hospital institutional review board. Forty-seven adult patients undergoing an MRI scan for a brain tumor indication were included. Contrast-enhanced MRI of the brain was performed at 3 T using both MPRAGE and Dixon uT 1 RESS. To control for any impact of contrast agent washout during the scan procedure, Dixon uT 1 RESS was acquired in approximately half the subjects immediately after MPRAGE, and in the other half immediately before MPRAGE. Image quality, artifacts, and lesion detection were scored by 3 readers, whereas lesion apparent signal-to-noise ratio and lesion-to-background Weber contrast were calculated from region-of-interest measurements.

RESULTS:

Image quality was not rated significantly different between MPRAGE and Dixon uT 1 RESS, whereas motion artifacts were slightly worse with Dixon uT 1 RESS. Comparing Dixon uT 1 RESS with MPRAGE, the respective values for mean lesion apparent signal-to-noise ratio were not significantly different (199.31 ± 99.05 vs 203.81 ± 110.23). Compared with MPRAGE, Dixon uT 1 RESS significantly increased the tumor-to-brain contrast (1.60 ± 1.18 vs 0.61 ± 0.47 when Dixon uT1RESS was acquired before MPRAGE and 1.94 ± 0.97 vs 0.82 ± 0.55 when Dixon uT 1 RESS was acquired after MPRAGE). In patients with metastatic disease, Dixon uT 1 RESS detected at least 1 enhancing brain lesion that was missed by MPRAGE on average in 24.7% of patients, whereas Dixon uT 1 RESS did not miss any lesions that were demonstrated by MPRAGE. Dixon uT 1 RESS better detected vascular and dural invasion in a small number of patients.

CONCLUSIONS:

In conclusion, brain tumors were significantly more conspicuous at 3 T using Dixon uT 1 RESS compared with MPRAGE, with an approximately 2.5-fold improvement in lesion-to-background contrast irrespective of sequence order. It outperformed MPRAGE for the detection of brain metastases, dural or vascular involvement. These results suggest that Dixon uT 1 RESS could prove to be a useful adjunct or alternative to existing neuroimaging techniques for the postcontrast evaluation of intracranial tumors.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Interpretación de Imagen Asistida por Computador Tipo de estudio: Observational_studies Límite: Adult / Humans Idioma: En Revista: Invest Radiol Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Interpretación de Imagen Asistida por Computador Tipo de estudio: Observational_studies Límite: Adult / Humans Idioma: En Revista: Invest Radiol Año: 2023 Tipo del documento: Article
...