Your browser doesn't support javascript.
loading
Extraction and determination of terpenoids from Zexie Decoction based on a porous organic cage-doped monolithic cartridge.
Wang, Laisen; Hou, Liyue; Han, Siliang; Guo, Huaizhong; Bai, Ligai.
Afiliación
  • Wang L; College of Pharmaceutical Sciences, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, Hebei University, Baoding 071002, China.
  • Hou L; College of Pharmaceutical Sciences, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, Hebei University, Baoding 071002, China.
  • Han S; Affiliated Hospital of Hebei University, Baoding 071002, China.
  • Guo H; College of Pharmaceutical Sciences, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, Hebei University, Baoding 071002, China.
  • Bai L; College of Pharmaceutical Sciences, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, Hebei University, Baoding 071002, China. Electronic address: bailigai@163.com.
Article en En | MEDLINE | ID: mdl-36863242
ABSTRACT
A monolithic solid-phase extraction (SPE) cartridge packed with a composite adsorbent was fabricated via polymerization using dodecene as the monomer with the porous organic cage (POC) material doped, combing with an analytical column through a high-performance liquid chromatography (HPLC) instrument, which was used for the online extraction and separation of 23-acetyl alismol C, atractylodes lactone II and atractylodes lactone III from Zexie Decoction. The POC-doped adsorbent shows porous structure with a relatively high specific surface area of 85.50 m2/g, which was obtained from the characterizations of a scanning electron microscope and an automatic surface area and porosity analyser. Efficient extraction and separation of three target terpenoids was achieved by an online SPE-HPLC method based on the POC-doped cartridge, which exhibits strong matrix-removal ability and good terpenoids-retention ability with a high adsorption capacity, due to the interactions of hydrogen bond and hydrophobicity between the terpenoids and the POC-doped adsorbent. Method validation shows good linearity (r ≥ 0.9998) of the regression equation, and high accuracy with the spiked recovery in the range of 99.2 %-100.8 % of the proposed method. Compared to the generally disposable adsorbent, this work fabricated a reusable monolithic cartridge, which can be used for at least 100 times, with the RSD based on the peak area of the three terpenoids less than 6.6 %.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Terpenos Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Terpenos Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article País de afiliación: China
...