Your browser doesn't support javascript.
loading
Clinical predictors of incomplete coronary sinus lead removal during transvenous lead extraction in patients with cardiac resynchronization therapy.
Hayashi, Katsuhide; Younis, Arwa; Callahan, Thomas; Baranowski, Bryan; Martin, David O; Nakhla, Shady; Wilkoff, Bruce L.
Afiliación
  • Hayashi K; Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
  • Younis A; Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
  • Callahan T; Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
  • Baranowski B; Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
  • Martin DO; Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
  • Nakhla S; Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
  • Wilkoff BL; Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio. Electronic address: wilkofb@ccf.org.
Heart Rhythm ; 20(6): 872-878, 2023 06.
Article en En | MEDLINE | ID: mdl-36933853
BACKGROUND: Reports of coronary sinus (CS) lead removal include small studies with short implant durations. Procedural outcomes for mature CS leads removed with long duration implantation are unavailable. OBJECTIVE: The purpose of this study was to examine the safety, efficacy, and clinical predictors of incomplete CS lead removal by transvenous lead extraction (TLE) in a large long implant duration cardiac resynchronization therapy patient cohort. METHODS: Consecutive patients with cardiac resynchronization therapy devices in the Cleveland Clinic Prospective TLE Registry who had TLE between 2013 and 2022 were included in the analysis. RESULTS: CS leads (N = 231; implant duration 6.1 ± 4.0 years) removed from 226 patients were included, using powered sheaths for 137 leads (59.3%). Complete CS lead extraction success was achieved in 95.2% of leads (n = 220) and in 95.6% of patients (n = 216). Major complications occurred in 5 patients (2.2%). Patients who had the CS lead extracted first had significantly higher incomplete removal rates than when the other leads were first removed. Multivariable analysis showed that older CS lead age (odds ratio 1.35; 95% confidence interval 1.01-1.82; P = .03) and removal of the first CS lead (odds ratio 7.48; 95% confidence interval 1.02-54.95; P = .045) were independent predictors of incomplete CS lead removal. CONCLUSION: The complete and safe lead removal rate of long implant duration CS leads by TLE was 95%. However, CS lead age and the order in which leads were extracted were the independent predictors of incomplete CS lead removal. Therefore, before the CS lead is extracted, physicians should first extract the leads from the other chambers and use powered sheaths.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Desfibriladores Implantables / Seno Coronario / Terapia de Resincronización Cardíaca Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Heart Rhythm Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Marcapaso Artificial / Desfibriladores Implantables / Seno Coronario / Terapia de Resincronización Cardíaca Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Heart Rhythm Año: 2023 Tipo del documento: Article
...