Your browser doesn't support javascript.
loading
Deep Learning-Based Algorithm for Automatic Detection of Pulmonary Embolism in Chest CT Angiograms.
Grenier, Philippe A; Ayobi, Angela; Quenet, Sarah; Tassy, Maxime; Marx, Michael; Chow, Daniel S; Weinberg, Brent D; Chang, Peter D; Chaibi, Yasmina.
Afiliación
  • Grenier PA; Department of Clinical Research and Innovation, Foch Hospital Suresnes, Versailles Saint Quentin University, 78000 Versailles, France.
  • Ayobi A; Avicenna.AI, 13600 La Ciotat, France.
  • Quenet S; Avicenna.AI, 13600 La Ciotat, France.
  • Tassy M; Avicenna.AI, 13600 La Ciotat, France.
  • Marx M; Avicenna.AI, 13600 La Ciotat, France.
  • Chow DS; Department of Radiological Sciences, University of California Irvine, Irvine, CA 92697, USA.
  • Weinberg BD; Center for Artificial Intelligence in Diagnostic Medicine, University of California Irvine, Irvine, CA 92697, USA.
  • Chang PD; Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA 30322, USA.
  • Chaibi Y; Department of Radiological Sciences, University of California Irvine, Irvine, CA 92697, USA.
Diagnostics (Basel) ; 13(7)2023 Apr 03.
Article en En | MEDLINE | ID: mdl-37046542
ABSTRACT

PURPOSE:

Since the prompt recognition of acute pulmonary embolism (PE) and the immediate initiation of treatment can significantly reduce the risk of death, we developed a deep learning (DL)-based application aimed to automatically detect PEs on chest computed tomography angiograms (CTAs) and alert radiologists for an urgent interpretation. Convolutional neural networks (CNNs) were used to design the application. The associated algorithm used a hybrid 3D/2D UNet topology. The training phase was performed on datasets adequately distributed in terms of vendors, patient age, slice thickness, and kVp. The objective of this study was to validate the performance of the algorithm in detecting suspected PEs on CTAs.

METHODS:

The validation dataset included 387 anonymized real-world chest CTAs from multiple clinical sites (228 U.S. cities). The data were acquired on 41 different scanner models from five different scanner makers. The ground truth (presence or absence of PE on CTA images) was established by three independent U.S. board-certified radiologists.

RESULTS:

The algorithm correctly identified 170 of 186 exams positive for PE (sensitivity 91.4% [95% CI 86.4-95.0%]) and 184 of 201 exams negative for PE (specificity 91.5% [95% CI 86.8-95.0%]), leading to an accuracy of 91.5%. False negative cases were either chronic PEs or PEs at the limit of subsegmental arteries and close to partial volume effect artifacts. Most of the false positive findings were due to contrast agent-related fluid artifacts, pulmonary veins, and lymph nodes.

CONCLUSIONS:

The DL-based algorithm has a high degree of diagnostic accuracy with balanced sensitivity and specificity for the detection of PE on CTAs.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_venous_thromboembolic_disease Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Diagnostics (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_venous_thromboembolic_disease Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Diagnostics (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Francia
...