Your browser doesn't support javascript.
loading
Ratiometric detection of I- using a dysprosium-based metal-organic framework with a single emission center.
Guo, Qing-Zhong; Yi, Feng-Ying; Zhang, Meng-Yao; Guo, Jun-Fang; Luo, Fa-Liang.
Afiliación
  • Guo QZ; Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430205, China. junfangguo@aliyun.com.
  • Yi FY; Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430205, China. junfangguo@aliyun.com.
  • Zhang MY; Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430205, China. junfangguo@aliyun.com.
  • Guo JF; Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430205, China. junfangguo@aliyun.com.
  • Luo FL; State Key Laboratory of High-efficiency Utilization of Coal and Green Chemical Engineering, Ningxia University, Yinchuan, 750021, China. fllnxu@sina.com.
Dalton Trans ; 52(18): 6061-6066, 2023 May 09.
Article en En | MEDLINE | ID: mdl-37057644
In this study, a dysprosium-based metal-organic framework (MOF) sensor (Dy-MOF) was developed for the ratiometric detection of I- in aqueous medium. Upon excitation at 230 nm, Dy-MOF shows two dominant emission bands at 464 nm and 574 nm assigned to (4F, 4D)5/2 → 6H9/2 + 6F11/2 and 4F9/2 → 6H13/2 transition of Dy3+, respectively, which have different sensitivities toward iodide ions. The introduction of I- slightly weakened the blue emission at 464 nm and significantly quenched the yellow emission at 574 nm. Thus, ratiometric sensing for iodide was realized using the yellow-to-blue intensity ratio of Dy3+. Dy-MOF exhibits superior sensing behavior towards I- with high selectivity, sensitivity and low detection limit (24 nM). This study also provides a strategy for the construction of a ratiometric sensor with dual-emission bands originating from only one emission center.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Dalton Trans Asunto de la revista: QUIMICA Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Dalton Trans Asunto de la revista: QUIMICA Año: 2023 Tipo del documento: Article País de afiliación: China
...