Your browser doesn't support javascript.
loading
Femur reconstruction in 3D ultrasound for orthopedic surgery planning.
Gebhardt, Christian; Göttling, Lara; Buchberger, Lukas; Ziegler, Christian; Endres, Felix; Wuermeling, Quirin; Holzapfel, Boris M; Wein, Wolfgang; Wagner, Ferdinand; Zettinig, Oliver.
Afiliación
  • Gebhardt C; ImFusion GmbH, Munich, Germany. gebhardt@imfusion.com.
  • Göttling L; Musculoskeletal University Center Munich, Department of Orthopedics and Trauma Surgery, Ludwig-Maximilians-University Munich, Munich, Germany.
  • Buchberger L; OT Medizintechnik GmbH, Munich, Germany.
  • Ziegler C; Musculoskeletal University Center Munich, Department of Orthopedics and Trauma Surgery, Ludwig-Maximilians-University Munich, Munich, Germany.
  • Endres F; Musculoskeletal University Center Munich, Department of Orthopedics and Trauma Surgery, Ludwig-Maximilians-University Munich, Munich, Germany.
  • Wuermeling Q; Musculoskeletal University Center Munich, Department of Orthopedics and Trauma Surgery, Ludwig-Maximilians-University Munich, Munich, Germany.
  • Holzapfel BM; Musculoskeletal University Center Munich, Department of Orthopedics and Trauma Surgery, Ludwig-Maximilians-University Munich, Munich, Germany.
  • Wein W; ImFusion GmbH, Munich, Germany.
  • Wagner F; Musculoskeletal University Center Munich, Department of Orthopedics and Trauma Surgery, Ludwig-Maximilians-University Munich, Munich, Germany.
  • Zettinig O; Department of Pediatric Surgery, Dr. von Hauner Children's Hospital, Ludwig-Maximilians-University Munich, Munich, Germany.
Int J Comput Assist Radiol Surg ; 18(6): 1001-1008, 2023 Jun.
Article en En | MEDLINE | ID: mdl-37079246
ABSTRACT

PURPOSE:

Derotation varisation osteotomy of the proximal femur in pediatric patients usually relies on 2-dimensional X-ray imaging, as CT and MRI still are disadvantageous when applied in small children either due to a high radiation exposure or the need of anesthesia. This work presents a radiation-free non-invasive tool to 3D-reconstruct the femur surface and measure relevant angles for orthopedic diagnosis and surgery planning from 3D ultrasound scans instead.

METHODS:

Multiple tracked ultrasound recordings are segmented, registered and reconstructed to a 3D femur model allowing for manual measurements of caput-collum-diaphyseal (CCD) and femoral anteversion (FA) angles. Novel contributions include the design of a dedicated phantom model to mimic the application ex vivo, an iterative registration scheme to overcome movements of a relative tracker only attached to the skin, and a technique to obtain the angle measurements.

RESULTS:

We obtained sub-millimetric surface reconstruction accuracy from 3D ultrasound on a custom 3D-printed phantom model. On a pre-clinical pediatric patient cohort, angular measurement errors were [Formula see text] and eventually [Formula see text] for CCD and FA angles, respectively, both within the clinically acceptable range. To obtain these results, multiple refinements of the acquisition protocol were necessary, ultimately reaching success rates of up to 67% for achieving sufficient surface coverage and femur reconstructions that allow for geometric measurements.

CONCLUSION:

Given sufficient surface coverage of the femur, clinically acceptable characterization of femoral anatomy is feasible from non-invasive 3D ultrasound. The acquisition protocol requires leg repositioning, which can be overcome using the presented algorithm. In the future, improvements of the image processing pipeline and more extensive surface reconstruction error assessments could enable more personalized orthopedic surgery planning using cutting templates.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagenología Tridimensional Tipo de estudio: Diagnostic_studies / Guideline Límite: Child / Humans Idioma: En Revista: Int J Comput Assist Radiol Surg Asunto de la revista: RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagenología Tridimensional Tipo de estudio: Diagnostic_studies / Guideline Límite: Child / Humans Idioma: En Revista: Int J Comput Assist Radiol Surg Asunto de la revista: RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Alemania
...