Your browser doesn't support javascript.
loading
Comparison of dosimetric parameters and robustness for rotational errors in fractionated stereotactic irradiation using automated noncoplanar volumetric modulated arc therapy for patients with brain metastases: single- versus multi-isocentric technique.
Yamamoto, Yuki; Ohira, Shingo; Kanayama, Naoyuki; Inui, Shoki; Ueda, Yoshihiro; Koike, Yuhei; Miyazaki, Masayoshi; Nishio, Teiji; Koizumi, Masahiko; Konishi, Koji.
Afiliación
  • Yamamoto Y; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
  • Ohira S; Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan. oohira-si@mc.pref.osaka.jp.
  • Kanayama N; Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
  • Inui S; Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
  • Ueda Y; Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
  • Koike Y; Department of Radiology, Kansai Medical University, Osaka, Japan.
  • Miyazaki M; Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
  • Nishio T; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
  • Koizumi M; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
  • Konishi K; Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
Radiol Phys Technol ; 16(2): 310-318, 2023 Jun.
Article en En | MEDLINE | ID: mdl-37093409
ABSTRACT
To compare the dosimetric parameters of automated noncoplanar volumetric modulated arc therapy plans using single-isocentric (SIC) and multi-isocentric (MIC) techniques for patients with two brain metastases (BMs) in stereotactic irradiation and to evaluate the robustness of rotational errors. The SIC and MIC plans were retrospectively generated (35 Gy/five fractions) for 58 patients. Subsequently, a receiver operating characteristic curve analysis between the tumor surface distance (TSD) and V25Gy was performed to determine the thresholds for the brain tissue. The SIC and MIC plans were recalculated based on the rotational images to evaluate the dosimetric impact of rotational error. The MIC plans showed better brain tissue sparing for TSD > 6.6 cm. The SIC plans provided a significantly better conformity index for TSD ≤ 6.6 cm, while significantly lower gradient index was obtained (3.22 ± 0.56vs. 3.30 ± 0.57, p < 0.05) in the MIC plans with TSD > 6.6 cm. For organs at risk (OARs) (brainstem, chiasm, lens, optic nerves, and retinas), D0.1 cc was significantly lower (p < 0.05) in the MIC plans than in the SIC plans. The prescription dose could be delivered (D99%) to the gross tumor volume (GTV) for patients with TSD ≤ 6.6 cm when the rotational error was < 1°, whereas 31% of the D99% of GTV fell below the prescription dose with TSD > 6.6 cm. MIC plans can be an optimal approach for reducing doses to OARs and providing robustness against rotational errors in BMs with TSD > 6.6 cm.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Radiocirugia / Radioterapia de Intensidad Modulada Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Radiol Phys Technol Asunto de la revista: BIOFISICA / RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Radiocirugia / Radioterapia de Intensidad Modulada Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Radiol Phys Technol Asunto de la revista: BIOFISICA / RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Japón
...