Your browser doesn't support javascript.
loading
Sonorheometry versus rotational thromboelastometry in trauma: a comparison of diagnostic and prognostic performance.
Rossetto, Andrea; Wohlgemut, Jared M; Brohi, Karim; Davenport, Ross.
Afiliación
  • Rossetto A; Centre for Trauma Sciences, Blizard Institute, Queen Mary University of London, London, UK; Barts Health National Health Service Trust, London, UK. Electronic address: andrea.rossetto@qmul.ac.uk.
  • Wohlgemut JM; Centre for Trauma Sciences, Blizard Institute, Queen Mary University of London, London, UK; Barts Health National Health Service Trust, London, UK.
  • Brohi K; Centre for Trauma Sciences, Blizard Institute, Queen Mary University of London, London, UK; Barts Health National Health Service Trust, London, UK.
  • Davenport R; Centre for Trauma Sciences, Blizard Institute, Queen Mary University of London, London, UK; Barts Health National Health Service Trust, London, UK.
J Thromb Haemost ; 21(8): 2114-2125, 2023 08.
Article en En | MEDLINE | ID: mdl-37164268
ABSTRACT

BACKGROUND:

Rotational thromboelastometry (ROTEM) is used to rapidly identify trauma-induced coagulopathy (TIC) and direct targeted interventions in hemorrhaging trauma patients. A novel technology, Quantra System (HemoSonics), utilizes sonic estimation of elasticity via resonance sonorheometry, avoids mechanical clot interference, and may increase diagnostic accuracy, but there are limited data on bleeding in major trauma patients.

OBJECTIVES:

To compare the performance of Quantra with that of ROTEM for rapid diagnosis of TIC and prediction of transfusion requirements and mortality.

METHODS:

Samples were collected from adult trauma patients enrolled in a perpetual cohort study upon admission to a single level 1 trauma center between 2020 and 2021. Samples were analyzed using Quantra, ROTEM, multiple electrode aggregometry, and conventional coagulation assays.

RESULTS:

Samples from 209 patients were analyzed. Correlations were strong between Quantra and ROTEM parameters (for all, p < .001) clot stiffness (CS) and tissue factor-activated ROTEM (EXTEM) clot amplitude at 5 minutes (A5) (r = 0.90); fibrinogen contribution to CS and tissue factor-activated ROTEM with cytochalasin D (FIBTEM) A5 (r = 0.85); and platelet contribution to CS and EXTEM-FIBTEM A5 (r = 0.73). Although CS showed higher discrimination than EXTEM A5 in detecting TIC (international normalized ratio, >1.2; area under the receiver operating characteristic curve, 0.83 vs 0.79; p = .038), the ability of fibrinogen contribution to CS to detect hypofibrinogenemia (a fibrinogen level of <2g/L) was good but lower than that of FIBTEM A5 (area under the receiver operating characteristic curve, 0.79 vs 0.84; p = .027). There was no difference between Quantra and ROTEM in detecting a platelet count of <150 × 109/L, predicting rapid transfusion or mortality at 6 hours.

CONCLUSION:

Quantra and ROTEM have similar diagnostic performances in evaluating TIC and predicting clinically relevant outcomes. Larger studies are required to determine the utility of Quantra for goal-directed treatment of TIC.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tromboelastografía / Trastornos de la Coagulación Sanguínea Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Humans Idioma: En Revista: J Thromb Haemost Asunto de la revista: HEMATOLOGIA Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tromboelastografía / Trastornos de la Coagulación Sanguínea Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Humans Idioma: En Revista: J Thromb Haemost Asunto de la revista: HEMATOLOGIA Año: 2023 Tipo del documento: Article
...