Your browser doesn't support javascript.
loading
Characterization and clinical utility of different collimator shapes in accelerator-based BNCT systems for head and neck cancer.
Komori, Shinya; Hirose, Katsumi; Takeuchi, Akihiko; Kato, Ryohei; Motoyanagi, Tomoaki; Yamazaki, Yuhei; Sato, Mariko; Kato, Takahiro; Takai, Yoshihiro.
Afiliación
  • Komori S; Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan. Electronic address: skomori.0922@gmail.com.
  • Hirose K; Department of Radiation Oncology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan; Department of Radiation Oncology, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori 036-8562, Japan.
  • Takeuchi A; Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan.
  • Kato R; Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan.
  • Motoyanagi T; Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan.
  • Yamazaki Y; Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan.
  • Sato M; Department of Radiation Oncology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan; Department of Radiation Oncology, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori 036-8562, Japan.
  • Kato T; Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan; School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima, Fukushima 960-8516, Japan.
  • Takai Y; Department of Radiation Oncology, Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan.
Phys Med ; 112: 102625, 2023 Aug.
Article en En | MEDLINE | ID: mdl-37331083
ABSTRACT
NeuCure® is the only accelerator-based boron neutron capture therapy (BNCT) system in the world with pharmaceutical approval. Until now, only flat collimators (FCs) on the patient side have been installed. However, in some cases of head and neck cancer patients, positioning the patient close enough to the collimator when using FCs was difficult. Thus, there are concerns about the prolongation of the irradiation time and overdose to normal tissues. To address these issues, a collimator with a convex-extended section on the patient side (extended collimators [ECs]) was developed, and its pharmaceutical approval was obtained in February 2022. This study evaluated the physical characterization and usefulness of each collimator using a simple geometry water phantom model and human model. In the water phantom model, the thermal neutron fluxes at 2 cm depth on the central axis were 5.13 × 108, 6.79 × 108, 1.02 × 109, and 1.17 × 109n/cm2/s for FC(120), FC(150), EC50(120), and EC100(120), respectively, when the distance from the irradiation aperture was kept constant at 18 cm. With ECs, the relative off-axis thermal neutron flux decreased steeply. In the hypopharyngeal cancer human model, the tumor dose changes were within <2%, but the maximum oral mucosa doses were 7.79, 8.51, 6.76, and 4.57 Gy-Eq, respectively. The irradiation times were 54.3, 41.3, 29.2, and 24.8 min, respectively. In cases where positioning the patient close to the collimator is difficult, the use of ECs may reduce the dose to normal tissues and shorten the irradiation time.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Terapia por Captura de Neutrón de Boro / Neoplasias de Cabeza y Cuello Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Terapia por Captura de Neutrón de Boro / Neoplasias de Cabeza y Cuello Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2023 Tipo del documento: Article
...