A protocol for tactile function assessment using JVP domes: Feasibility study and preliminary results.
Wang, Yung-Jung; Sung, Chung-Tung; Huang, Jian-Jia; Pei, Yu-Cheng; Chang, Bao-Luen.
Afiliación
  • Wang YJ; School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
  • Sung CT; Department of Medical Education, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan, Taiwan.
  • Huang JJ; School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
  • Pei YC; Department of Medical Education, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan, Taiwan.
  • Chang BL; Department of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital at Linkou Medical Center, Taoyuan, Taiwan.
Brain Behav ; 13(8): e3123, 2023 08.
Article en En | MEDLINE | ID: mdl-37334446
ABSTRACT

BACKGROUND:

Touch is a crucial sense for perceiving the spatial characteristics of objects. The JVP dome was developed to evaluate tactile spatial acuity using a grating orientation task. There were few studies depicting sequences and details for the entire task, including practice, training, and testing sessions. Therefore, we proposed and elaborated a protocol for the grating orientation task using the staircase method, which required fewer testing trials compared with the method of constant stimuli.

METHODS:

Twenty-three healthy participants were enrolled in this experiment. The JVP domes with 11 different groove widths were used. Tactile discrimination thresholds were estimated using a two-down-one-up staircase method. The experiment comprised practice, training, and testing sessions, conducted by trained examiners who performed grating stimulation on participants' index fingerpads.

RESULTS:

All participants passed the required accuracy in the practice and training sessions. Eight transition points were obtained in the testing session for each participant. The tactile discrimination thresholds were determined from the last six transition points. We obtained the mean tactile discrimination threshold as 1.8 ± 0.75 mm (n = 23). The results demonstrated that the proposed protocol was successfully applied to assess tactile discrimination thresholds.

CONCLUSIONS:

The present study investigated the protocol of grating orientation tasks requiring a small number of testing trials with the assurance of the task quality. The feasibility study and preliminary results indicated the potentiality of this protocol for future clinical application.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tacto / Percepción del Tacto Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Brain Behav Año: 2023 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tacto / Percepción del Tacto Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Brain Behav Año: 2023 Tipo del documento: Article País de afiliación: Taiwán
...