Detailed Comparison of Xenon APPI (9.6/8.4 eV), Krypton APPI (10.6/10.0 eV), APCI, and APLI (266 nm) for Gas Chromatography High Resolution Mass Spectrometry of Standards and Complex Mixtures.
Neumann, Anika; Tiemann, Ole; Hansen, Helly J; Rüger, Christopher P; Zimmermann, Ralf.
Afiliación
  • Neumann A; Joint Mass Spectrometry Centre/Chair of Analytical Chemistry, University of Rostock, 18059 Rostock, Germany.
  • Tiemann O; Department Life, Light & Matter (LL&M), University of Rostock, 18059 Rostock, Germany.
  • Hansen HJ; Joint Mass Spectrometry Centre/Chair of Analytical Chemistry, University of Rostock, 18059 Rostock, Germany.
  • Rüger CP; Department Life, Light & Matter (LL&M), University of Rostock, 18059 Rostock, Germany.
  • Zimmermann R; Joint Mass Spectrometry Centre/Chair of Analytical Chemistry, University of Rostock, 18059 Rostock, Germany.
J Am Soc Mass Spectrom ; 34(8): 1632-1646, 2023 Aug 02.
Article en En | MEDLINE | ID: mdl-37395530
Photoionization schemes for mass spectrometry, either by laser or discharge lamps, have been widely examined and deployed. In this work, the ionization characteristics of a xenon discharge lamp (Xe-APPI, 9.6/8.4 eV) have been studied and compared to established ionization schemes, such as atmospheric pressure chemical ionization, atmospheric pressure photoionization with a krypton discharge lamp (Kr-APPI, 10.6/10 eV) and atmospheric pressure laser ionization (266 nm). Addressing the gas-phase ionization behavior has been realized by gas chromatography coupled to high-resolution mass spectrometry without the usage of a dopant. For standard substances, it has been found that Xe-APPI is able to ionize a broad range of polycyclic aromatic hydrocarbons as well as their heteroatom-containing and alkylated derivatives. However, thiol and ester compounds could not be detected. Moreover, Xe-APPI revealed a high tendency to generate oxygenated artifacts, most likely due to a VUV absorption band of oxygen at 148 nm. Beneficially, almost no chemical background, commonly caused by APCI or Kr-APPI due to column blood, plasticizers or impurities, is observed. This advantage is noteworthy for evolved gas analysis without preseparation or for chromatographic coelution. For the complex mixtures, Xe-APPI revealed the predominant generation of radical cations via direct photoionization with a high selectivity toward aromatic core structures with low alkylation. Interestingly, both Xe-APPI and Kr-APPI could sensitively detect sterane cycloalkanes, validated by gas chromatographic retention. The narrowly ionized chemical space could let Xe-APPI find niche applications, e.g., for strongly contaminated samples to reduce the background.