Your browser doesn't support javascript.
loading
Comparison in conjunctival-Tenon's capsule thickness, anterior scleral thickness and ciliary muscle dimensions between Caucasians and Hispanic by optical coherence tomography.
Fernández-Vigo, José Ignacio; Fernández-Aragón, Susana; Burgos-Blasco, Bárbara; Ly-Yang, Fernando; De-Pablo-Gómez-de-Liaño, Lucía; Almorín-Fernández-Vigo, Ignacio; Martínez-de-la-Casa, José María; Fernández-Vigo, José Ángel.
Afiliación
  • Fernández-Vigo JI; Centro Internacional de Oftalmología Avanzada, Zurbano 71 Street, 28010, Madrid, Spain. jfvigo@hotmail.com.
  • Fernández-Aragón S; Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain. jfvigo@hotmail.com.
  • Burgos-Blasco B; Centro Internacional de Oftalmología Avanzada, Zurbano 71 Street, 28010, Madrid, Spain.
  • Ly-Yang F; Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain.
  • De-Pablo-Gómez-de-Liaño L; Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, Spain.
  • Almorín-Fernández-Vigo I; Centro Internacional de Oftalmología Avanzada, Zurbano 71 Street, 28010, Madrid, Spain.
  • Martínez-de-la-Casa JM; Department of Ophthalmology, Hospital 12 de Octubre, Madrid, Spain.
  • Fernández-Vigo JÁ; Centro Internacional de Oftalmología Avanzada, Badajoz, Spain.
Int Ophthalmol ; 43(11): 3969-3977, 2023 Nov.
Article en En | MEDLINE | ID: mdl-37405569
ABSTRACT

PURPOSE:

To investigate the differences in the dimensions of the anterior ocular segment, and specifically in conjunctival-Tenon's capsule thickness (CTT), anterior scleral thickness (AST) and ciliary muscle thickness (CMT), between Caucasian and Hispanic subjects using swept-source optical coherence tomography (SS-OCT).

METHODS:

Cross-sectional study including 53 Hispanic and 60 Caucasian healthy participants, matched by age, sex and refractive error, who underwent a complete ophthalmological examination. CTT, AST and CMT were manually measured in the temporal and nasal quadrants at 0, 1, 2 and 3 mm from the scleral spur using SS-OCT.

RESULTS:

Mean age and refractive error were 38.7 ± 12.3 years and -1.05 ± 2.6 diopters, and 41.8 ± 11.7 years and -0.50 ± 2.6 diopters for the Hispanic and Caucasians, respectively (p = 0.165 and p = 0.244). The CTT was increased in the temporal quadrant in the Hispanic group in the three studied regions (CTT1, CTT2 and CTT3; being the means 223.0 ± 68.4, 215.3 ± 66.4 and 203.8 ± 67.1 µm versus 190.8 ± 51.0, 189.4 ± 53.2 and 187.4 ± 55.3 µm respectively; p < 0.001). Larger AST values were observed in the temporal quadrant in the Hispanic group (AST2 559.8 ± 80.8 µm and AST3 591.6 ± 83.0 µm) compared to the Caucasian group (520.7 ± 50.1 and 558.9 ± 54.7 respectively; p ≤ 0.022). No differences were observed in the nasal quadrant for CTT, AST1 and AST3 (p ≥ 0.076). No differences emerged in the CM dimensions (p ≥ 0.055).

CONCLUSION:

CTT and AST measurements were thicker in the temporal quadrant of Hispanic patients compared to Caucasians. This could have implications for the pathogenesis of different ocular diseases.