Your browser doesn't support javascript.
loading
Self-supervised learning of accelerometer data provides new insights for sleep and its association with mortality.
Yuan, Hang; Plekhanova, Tatiana; Walmsley, Rosemary; Reynolds, Amy C; Maddison, Kathleen J; Bucan, Maja; Gehrman, Philip; Rowlands, Alex; Ray, David W; Bennett, Derrick; McVeigh, Joanne; Straker, Leon; Eastwood, Peter; Kyle, Simon D; Doherty, Aiden.
Afiliación
  • Yuan H; Nuffield Department of Population Health, University of Oxford, UK.
  • Plekhanova T; Big Data Institute, Li Ka Shing Centre for Health Information and Discovery, University of Oxford, UK.
  • Walmsley R; Diabetes Research Centre, University of Leicester, UK.
  • Reynolds AC; Nuffield Department of Population Health, University of Oxford, UK.
  • Maddison KJ; Big Data Institute, Li Ka Shing Centre for Health Information and Discovery, University of Oxford, UK.
  • Bucan M; College of Medicine and Public Health, Flinders University, Australia.
  • Gehrman P; Centre of Sleep Science, School of Human Sciences, University of Western Australia, Australia.
  • Rowlands A; West Australian Sleep Disorders Research Institute, Department of Pulmonary Physiology, Sir Charles Gairdner Hospital, Australia.
  • Ray DW; Department of Genetics, University of Pennsylvania, USA.
  • Bennett D; Department of Psychiatry, University of Pennsylvania, USA.
  • McVeigh J; Diabetes Research Centre, University of Leicester, UK.
  • Straker L; NIHR Leicester Biomedical Research Centre, University of Leicester, UK.
  • Eastwood P; NIHR Oxford Biomedical Research Centre, John Radcliffe Hospital, Oxford, UK.
  • Kyle SD; Nuffield Department of Population Health, University of Oxford, UK.
  • Doherty A; Medical Research Council Population Health Research Unit, University of Oxford, UK.
medRxiv ; 2023 Jul 08.
Article en En | MEDLINE | ID: mdl-37461532
ABSTRACT

Background:

Sleep is essential to life. Accurate measurement and classification of sleep/wake and sleep stages is important in clinical studies for sleep disorder diagnoses and in the interpretation of data from consumer devices for monitoring physical and mental well-being. Existing non-polysomnography sleep classification techniques mainly rely on heuristic methods developed in relatively small cohorts. Thus, we aimed to establish the accuracy of wrist-worn accelerometers for sleep stage classification and subsequently describe the association between sleep duration and efficiency (proportion of total time asleep when in bed) with mortality outcomes.

Methods:

We developed and validated a self-supervised deep neural network for sleep stage classification using concurrent laboratory-based polysomnography and accelerometry data from three countries (Australia, the UK, and the USA). The model was validated within-cohort using subject-wise five-fold cross-validation for sleep-wake classification and in a three-class setting for sleep stage classification wake, rapid-eye-movement sleep (REM), non-rapid-eye-movement sleep (NREM) and by external validation. We assessed the face validity of our model for population inference by applying the model to the UK Biobank with 100,000 participants, each of whom wore a wristband for up to seven days. The derived sleep parameters were used in a Cox regression model to study the association of sleep duration and sleep efficiency with all-cause mortality.

Findings:

After exclusion, 1,448 participant nights of data were used to train the sleep classifier. The difference between polysomnography and the model classifications on the external validation was 34.7 minutes (95% limits of agreement (LoA) -37.8 to 107.2 minutes) for total sleep duration, 2.6 minutes for REM duration (95% LoA -68.4 to 73.4 minutes) and 32.1 minutes (95% LoA -54.4 to 118.5 minutes) for NREM duration. The derived sleep architecture estimate in the UK Biobank sample showed good face validity. Among 66,214 UK Biobank participants, 1,642 mortality events were observed. Short sleepers (<6 hours) had a higher risk of mortality compared to participants with normal sleep duration (6 to 7.9 hours), regardless of whether they had low sleep efficiency (Hazard ratios (HRs) 1.69; 95% confidence intervals (CIs) 1.28 to 2.24 ) or high sleep efficiency (HRs 1.42; 95% CIs 1.14 to 1.77).

Interpretation:

Deep-learning-based sleep classification using accelerometers has a fair to moderate agreement with polysomnography. Our findings suggest that having short overnight sleep confers mortality risk irrespective of sleep continuity.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Health_technology_assessment / Prognostic_studies / Risk_factors_studies Aspecto: Ethics Idioma: En Revista: MedRxiv Año: 2023 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Health_technology_assessment / Prognostic_studies / Risk_factors_studies Aspecto: Ethics Idioma: En Revista: MedRxiv Año: 2023 Tipo del documento: Article País de afiliación: Reino Unido
...