Your browser doesn't support javascript.
loading
On timing-optimized SiPMs for Cherenkov detection to boost low cost time-of-flight PET.
Gundacker, Stefan; Borghi, Giacomo; Cherry, Simon R; Gola, Alberto; Lee, Daehee; Merzi, Stefano; Penna, Michele; Schulz, Volkmar; Kwon, Sun Il.
Afiliación
  • Gundacker S; Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstrae 55, D-52074 Aachen, Germany.
  • Borghi G; Fondazione Bruno Kessler, via Sommarive 18, Trento I-38123, Italy.
  • Cherry SR; Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, United States of America.
  • Gola A; Fondazione Bruno Kessler, via Sommarive 18, Trento I-38123, Italy.
  • Lee D; Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, United States of America.
  • Merzi S; Fondazione Bruno Kessler, via Sommarive 18, Trento I-38123, Italy.
  • Penna M; Fondazione Bruno Kessler, via Sommarive 18, Trento I-38123, Italy.
  • Schulz V; Dipartimento di Elettronica e Telecomunicazioni, Politecnico di Torino, Corso Duca degli Abruzzi 24, I-10129 Torino, Italy.
  • Kwon SI; Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstrae 55, D-52074 Aachen, Germany.
Phys Med Biol ; 68(16)2023 08 09.
Article en En | MEDLINE | ID: mdl-37467766
ABSTRACT
Objective.Recent SiPM developments and improved front-end electronics have opened new doors in TOF-PET with a focus on prompt photon detection. For instance, the relatively high Cherenkov yield of bismuth-germanate (BGO) upon 511 keV gamma interaction has triggered a lot of interest, especially for its use in total body positron emission tomography (PET) scanners due to the crystal's relatively low material and production costs. However, the electronic readout and timing optimization of the SiPMs still poses many questions. Lab experiments have shown the prospect of Cherenkov detection, with coincidence time resolutions (CTRs) of 200 ps FWHM achieved with small pixels, but lack system integration due to an unacceptable high power uptake of the used amplifiers.Approach.Following recent studies the most practical circuits with lower power uptake (<30 mW) have been implemented and the CTR performance with BGO of newly developed SiPMs from Fondazione Bruno Kessler tested. These novel SiPMs are optimized for highest single photon time resolution (SPTR).Main results.We achieved a best CTR FWHM of 123 ps for 2 × 2 × 3 mm3and 243 ps for 3 × 3 × 20 mm3BGO crystals. We further show that with these devices a CTR of 106 ps is possible using commercially available 3 × 3 × 20 mm3LYSOCe,Mg crystals. To give an insight in the timing properties of these SiPMs, we measured the SPTR with black coated PbF2of 2 × 2 × 3 mm3size. We confirmed an SPTR of 68 ps FWHM published in literature for standard devices and show that the optimized SiPMs can improve this value to 42 ps. Pushing the SiPM bias and using 1 × 1 mm2area devices we measured an SPTR of 28 ps FWHM.Significance.We have shown that advancements in readout electronics and SiPMs can lead to improved CTR with Cherenkov emitting crystals. Enabling time-of-flight with BGO will trigger a high interest for its use in low-cost and total-body PET scanners. Furthermore, owing to the prompt nature of Cherenkov emission, future CTR improvements are conceivable, for which a low-power electronic implementation is indispensable. In an extended discussion we will give a roadmap to best timing with prompt photons.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Fotones / Tomografía de Emisión de Positrones Tipo de estudio: Diagnostic_studies / Health_economic_evaluation Idioma: En Revista: Phys Med Biol Año: 2023 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Fotones / Tomografía de Emisión de Positrones Tipo de estudio: Diagnostic_studies / Health_economic_evaluation Idioma: En Revista: Phys Med Biol Año: 2023 Tipo del documento: Article País de afiliación: Alemania
...