Your browser doesn't support javascript.
loading
Efficacy of cap-assisted endoscopy for the visualization of the major duodenal papilla: a systematic review and meta-analysis.
Iqbal, Umair; Yodice, Michael; Ahmed, Zohaib; Lee-Smith, Wade; Adler, Douglas G; Confer, Bradley D.
Afiliación
  • Iqbal U; Division of Gastroenterology, WellSpan York Hospital, York, Pennsylvania, USA.
  • Yodice M; Division of Internal Medicine, Geisinger Medical Center, Danville, Pennsylvania, USA.
  • Ahmed Z; Department of Gastroenterology, University of Toledo Medical Center, Toledo, Ohio, USA.
  • Lee-Smith W; University Libraries, University of Toledo Medical Center, Toledo, Ohio, USA.
  • Adler DG; Center for Advanced Therapeutic Endoscopy (CATE), Centura Health, Porter Adventist Hospital, Peak Gastroenterology, Denver, Colorado, USA.
  • Confer BD; Division of Gastroenterology, Geisinger Medical Center, Danville, Pennsylvania, USA.
Gastrointest Endosc ; 98(6): 1004-1008, 2023 Dec.
Article en En | MEDLINE | ID: mdl-37544335
ABSTRACT
BACKGROUND AND

AIMS:

The current standard of practice is to use a duodenoscope for the evaluation of the major duodenal papilla (MDP). Recently, cap-assisted endoscopy (CAE), which uses a transparent cap at the tip of a standard front-viewing endoscope, has emerged as an alternative.

METHODS:

A systematic literature search was performed in several databases from inception to January 2023 to identify studies evaluating the efficacy of CAE for the evaluation of the MDP.

RESULTS:

Nine studies including 806 patients met our inclusion criteria. The pooled rate of technical success for CAE was 93.2% (95% confidence interval, 85.6-96.9; I2 = 84.6%). A subgroup analysis comparing CAE with a standard endoscope showed higher odds for the evaluation of the MDP with CAE (but not a duodenoscope, which was better than CAE) with an odds ratio of 57.294 (95% confidence interval, 17.767-184.755; I2 = 45.303%).

CONCLUSIONS:

CAE offers a significant advantage with high rates of complete MDP evaluation compared with standard forward-viewing endoscopy. However, CAE is associated with lower rates of success when compared with side-viewing endoscopes.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ampolla Hepatopancreática Tipo de estudio: Prognostic_studies / Systematic_reviews Límite: Humans Idioma: En Revista: Gastrointest Endosc Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ampolla Hepatopancreática Tipo de estudio: Prognostic_studies / Systematic_reviews Límite: Humans Idioma: En Revista: Gastrointest Endosc Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos
...