Radiologic and clinical outcomes of an arthroscopic bridging graft for irreparable rotator cuff tears with a modified MasonAllen stitch using a plantaris tendon autograft: a case series with minimum 2-year outcomes.
Seok, Hyun-Gyu; Park, Sam-Guk.
Afiliación
  • Seok HG; Department of Orthopedic Surgery, Yeungnam University Medical Center, Daegu, Korea.
  • Park SG; Department of Orthopedic Surgery, Yeungnam University Medical Center, Daegu, Korea.
Clin Shoulder Elb ; 26(4): 406-415, 2023 Dec.
Article en En | MEDLINE | ID: mdl-37559524
ABSTRACT

BACKGROUND:

Surgical management of a massive rotator cuff tear (RCT) is always challenging. This study describes the clinical and radiological outcomes of patients who underwent bridging grafts using a plantaris tendon for an irreparable RCT.

METHODS:

Thirteen patients with a massive RCT were treated with arthroscopic interposition of a folded plantaris tendon autograft between June 2017 and January 2020. For clinical evaluation, a visual analog scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, Disabilities of the Arm, Shoulder, and Hand (DASH) score, Constant-Murley score, and range of motion values were collected. For radiographic evaluation, standardized magnetic resonance imaging and ultrasonography were performed to check the integrity of the interposed tendon.

RESULTS:

A statistically significant improvement at the final follow-up was evident in scores for the VAS (-3.0, P=0.003), ASES (24.9, P=0.002), D ASH (-20.6, P=0.001), and Constant-Murley values (14.2, P=0.010). In addition, significant improvement was shown in postoperative flexion (17.3°, P=0.026) and external rotation (27.7°, P<0.001). In postoperative radiologic evaluations, the interposed tendons were intact at the last examination in 12 of the 13 patients. No complications related to donor sites were reported.

CONCLUSIONS:

An arthroscopic bridging graft for irreparable RCTs using a modified Mason-Allen stitch and a plantaris autograft resulted in improved short-term radiological and clinical outcomes. Graft integrity was maintained for up to 2 years in most patients. Level of evidence IV.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Clin Shoulder Elb Año: 2023 Tipo del documento: Article