Your browser doesn't support javascript.
loading
Validity, Reliability, and Sensitivity of Mobile Applications to Assess Change of Direction Speed.
Uysal, Hüseyin Sahin; Ojeda-Aravena, Alex; Ulas, Mehmet; Martín, Eduardo Báez-San; Ramirez-Campillo, Rodrigo.
Afiliación
  • Uysal HS; Department of Physical Education and Sports Education, Faculty of Sports Sciences, Burdur Mehmet Akif Ersoy University, Burdur, Turkey.
  • Ojeda-Aravena A; Physical Education School, Pontificia Universidad Católica de Valparaíso, Valparaíso, Chile.
  • Ulas M; Department of Physical Education and Sports Education, Faculty of Sports Sciences, Burdur Mehmet Akif Ersoy University, Burdur, Turkey.
  • Martín EB; Escuela de Educación, Carrera de Entrenador Deportivo, Universidad Viña del Mar, Viña del Mar, Chile.
  • Ramirez-Campillo R; Department of Sports Science, Universidad de Playa Ancha, Valparaíso, Chile.
J Hum Kinet ; 87: 217-228, 2023 Jul.
Article en En | MEDLINE | ID: mdl-37559771
ABSTRACT
This study aimed to assess the validity, reliability, and sensitivity of mobile applications for assessing change-of-direction speed (CODS) performance. Thirty college athletes performed two Illinois CODS tests during one session. Assessments were carried out simultaneously using six devices (the CODTimer app, Seconds Count app, StopwatchCamera app, two analog stopwatches, and timing gates). Validity analyses included Pearson's product-moment correlation analysis, a linear regression model, and Bland-Altman plots. Reliability analyses included the intraclass correlation coefficient (ICC), the coefficient of variation (CV%), and the paired-sample t test. Sensitivity analyses included the typical error and smallest worthwhile change (SWC). The results showed that validity, reliability, and sensitivity values were higher for the CODTimer app (r = 0.99, R2 = 0.99, mean bias = -0.03 ± 0.10, CV% = 3.21, ICC = 0.89, SWC rating good, p = 0.84) and the Seconds Count app (r = 0.99, R2 = 0.99, mean bias = -0.03 ± 0.08, CV% = 3.28, ICC = 0.88, SWC rating good, p = 0.84) relative to the StopwatchCamera app (r = 0.98, R2 = 0.97, mean bias = -0.11 ± 0.22, CV% = 3.43, ICC = 0.86, SWC rating marginal, p = 0.10), Analog Stopwatch 1 (r = 0.98, R2 = 0.96, mean bias = -0.09 ± 0.42, CV% = 2.95, ICC = 0.90, SWC rating good, p = 0.91), and Analog Stopwatch 2 (r = 0.99, R2 = 0.97, mean bias = -0.12 ± 0.88, CV% = 3.51, ICC = 0.87, SWC rating marginal, p = 0.96). In conclusion, compared to timing gates, the CODTimer app and Seconds Count app provided lower measurement bias and higher sensitivity for assessing CODS performance.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Hum Kinet Año: 2023 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Hum Kinet Año: 2023 Tipo del documento: Article País de afiliación: Turquía
...