Your browser doesn't support javascript.
loading
Electrospun compliant heparinized elastic vascular graft for improving the patency after implantation.
Qiu, Shouji; Du, Juan; Zhu, Tonghe; Zhang, Haibo; Chen, Sihao; Wang, Chunsheng; Chen, Dian; Lu, Shuyang.
Afiliación
  • Qiu S; Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, The Shanghai Institute of Cardiovascular Diseases, 1609 Xietu Rd., Shanghai 200032, PR China.
  • Du J; School of Chemistry and Chemical Engineering, Institute for Frontier Medical Technology, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China.
  • Zhu T; School of Chemistry and Chemical Engineering, Institute for Frontier Medical Technology, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China.
  • Zhang H; Department of Cardiothoracic Surgery, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, 1678 Dongfang Rd., Shanghai 200127, PR China.
  • Chen S; School of Chemistry and Chemical Engineering, Institute for Frontier Medical Technology, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, PR China.
  • Wang C; Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, The Shanghai Institute of Cardiovascular Diseases, 1609 Xietu Rd., Shanghai 200032, PR China. Electronic address: wang.chunsheng@zs-hospital.sh.cn.
  • Chen D; Department of Cardiothoracic Surgery, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, 1678 Dongfang Rd., Shanghai 200127, PR China. Electronic address: cdism221@163.com.
  • Lu S; Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University, The Shanghai Institute of Cardiovascular Diseases, 1609 Xietu Rd., Shanghai 200032, PR China. Electronic address: lu.shuyang@zs-hospital.sh.cn.
Int J Biol Macromol ; 253(Pt 1): 126598, 2023 Dec 31.
Article en En | MEDLINE | ID: mdl-37660861
ABSTRACT
The low patency rate after artificial blood vessel replacement is mainly due to the ineffective use of anticoagulant factors and the mismatch of mechanical compliance after transplantation. Electrospun nanofibers with biomimetic extracellular matrix three-dimensional structure and tunable mechanical strength are excellent carriers for heparin. In this work, we have designed and synthesized a series of biodegradable poly(ester-ether-urethane)ureas (BEPU), following compound with optimized constant concentration of heparin by homogeneous emulsion blending, then spun into the hybrid BEPU/heparin nanofibers tubular graft for replacing rats' abdominal aorta in situ for comprehensive performance evaluation. The results in vitro demonstrated that the electrospun L-PEUUH (LDI-based PEUU with heparin) vascular graft was of regular microstructure, optimum surface wettability, matched mechanical properties, reliable cytocompatibility, and strongest endothelialization in situ. Replacement of resected abdominal artery with the L-PEUUH vascular graft in rat showed that the graft was capable of homogeneous hybrid heparin and significantly promoted the stabilization of vascular endothelial cells (VECs) and vascular smooth muscle cells (VSMCs), as well as stabilizing the blood microenvironment. This research demonstrates the L-PEUUH vascular graft with substantial patency, indicating their potential for injured vascular healing.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis Vascular / Células Endoteliales Límite: Animals Idioma: En Revista: Int J Biol Macromol Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis Vascular / Células Endoteliales Límite: Animals Idioma: En Revista: Int J Biol Macromol Año: 2023 Tipo del documento: Article
...