Your browser doesn't support javascript.
loading
Increased accuracy in component positioning using an image-less robotic arm system in primary total knee arthroplasty: a retrospective study.
Mancino, Fabio; Rossi, Stefano Marco Paolo; Sangaletti, Rudy; Caredda, Matteo; Terragnoli, Flavio; Benazzo, Francesco.
Afiliación
  • Mancino F; Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, U.O. Ortopedia e Traumatologia, Fondazione Poliambulanza Via Bissolati 57, 25124, Brescia, Italy.
  • Rossi SMP; Department of Orthopaedics, The Orthopaedic Research Foundation of Western Australia (ORFWA), Fiona Stanley Hospital, Perth, WA, Australia.
  • Sangaletti R; Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, U.O. Ortopedia e Traumatologia, Fondazione Poliambulanza Via Bissolati 57, 25124, Brescia, Italy. rossi.smp@gmail.com.
  • Caredda M; Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, U.O. Ortopedia e Traumatologia, Fondazione Poliambulanza Via Bissolati 57, 25124, Brescia, Italy.
  • Terragnoli F; Università degli Studi di Pavia, Pavia, Italy.
  • Benazzo F; Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, U.O. Ortopedia e Traumatologia, Fondazione Poliambulanza Via Bissolati 57, 25124, Brescia, Italy.
Arch Orthop Trauma Surg ; 144(1): 393-404, 2024 Jan.
Article en En | MEDLINE | ID: mdl-37755480
ABSTRACT

BACKGROUND:

Robotic-assisted total knee arthroplasty (RTKA) and navigated total knee arthroplasty (NTKA) have shown improved knee alignment and reduced radiographic outliers. Recent studies have proven that conventional mechanical alignment may not be the optimal goal for every patient. The aim of this study was to compare the accuracy of the planned implant positioning of a novel image-less robotic technique with an established navigated technique (NTKA).

METHOD:

The study is a retrospective analysis of prospectively collected data that compared the implant positioning and lower-limb alignment of 86 image-less RTKA with 86 image-less NTKA. Radiographic analysis was performed to evaluate the lower-limb overall alignment, femoral and tibial components positioning in the coronal and sagittal planes. Outliers were evaluated with a cutoff of ± 3°.

RESULTS:

No difference was noted between the two groups for radiographic outliers within ± 3° from neutral (p = 0.098). The mean hip-knee-ankle angle deviation from target was 1.3° in the RTKA group compared to 1.9° in the NTKA (p < 0.001). Femoral sagittal deviation (femoral component flexion) was smaller in the RTKA group (0.9° vs 1.9°; p < 0.001). Similarly, tibial coronal deviation (0.8° vs 1.5°; p < 0.001) and tibial sagittal deviation (tibial slope) were smaller in the RTKA group compared to the NTKA group (0.9° vs 1.7°; p < 0.001).

CONCLUSIONS:

The RTKA group reported a substantial and significant reduced error from the planned target angles for both tibial and femoral components. No difference in terms of radiographic outliers was noted between navigation and robotic assistance.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Cirugía Asistida por Computador / Procedimientos Quirúrgicos Robotizados / Prótesis de la Rodilla Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Arch Orthop Trauma Surg Año: 2024 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Cirugía Asistida por Computador / Procedimientos Quirúrgicos Robotizados / Prótesis de la Rodilla Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Arch Orthop Trauma Surg Año: 2024 Tipo del documento: Article País de afiliación: Italia
...