Your browser doesn't support javascript.
loading
Geometrical Characterisation of TiO2-rGO Field-Effect Transistor as a Platform for Biosensing Applications.
Alim, Anis Amirah; Roslan, Roharsyafinaz; Nadzirah, Sh; Saidi, Lina Khalida; Menon, P Susthitha; Aziah, Ismail; Chang Fu, Dee; Sulaiman, Siti Aishah; Abdul Murad, Nor Azian; Hamzah, Azrul Azlan.
Afiliación
  • Alim AA; Institute of Microengineering and Nanoelectronics, National University of Malaysia, Bangi 43600, Selangor, Malaysia.
  • Roslan R; Institute of Microengineering and Nanoelectronics, National University of Malaysia, Bangi 43600, Selangor, Malaysia.
  • Nadzirah S; Institute of Microengineering and Nanoelectronics, National University of Malaysia, Bangi 43600, Selangor, Malaysia.
  • Saidi LK; Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar 01000, Perlis, Malaysia.
  • Menon PS; UKM Medical Molecular Biology Institute (UMBI), National University of Malaysia, Cheras 56000, Kuala Lumpur, Malaysia.
  • Aziah I; Institute of Microengineering and Nanoelectronics, National University of Malaysia, Bangi 43600, Selangor, Malaysia.
  • Chang Fu D; Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia.
  • Sulaiman SA; Institute of Microengineering and Nanoelectronics, National University of Malaysia, Bangi 43600, Selangor, Malaysia.
  • Abdul Murad NA; UKM Medical Molecular Biology Institute (UMBI), National University of Malaysia, Cheras 56000, Kuala Lumpur, Malaysia.
  • Hamzah AA; UKM Medical Molecular Biology Institute (UMBI), National University of Malaysia, Cheras 56000, Kuala Lumpur, Malaysia.
Micromachines (Basel) ; 14(9)2023 Aug 25.
Article en En | MEDLINE | ID: mdl-37763827
The performance of the graphene-based field-effect transistor (FET) as a biosensor is based on the output drain current (Id). In this work, the signal-to-noise ratio (SNR) was investigated to obtain a high-performance device that produces a higher Id value. Using the finite element method, a novel top-gate FET was developed in a three-dimensional (3D) simulation model with the titanium dioxide-reduced graphene oxide (TiO2-rGO) nanocomposite as the transducer material, which acts as a platform for biosensing application. Using the Taguchi mixed-level method in Minitab software (Version 16.1.1), eighteen 3D models were designed based on an orthogonal array L18 (6134), with five factors, and three and six levels. The parameters considered were the channel length, electrode length, electrode width, electrode thickness and electrode type. The device was fabricated using the conventional photolithography patterning technique and the metal lift-off method. The material was synthesised using the modified sol-gel method and spin-coated on top of the device. According to the results of the ANOVA, the channel length contributed the most, with 63.11%, indicating that it was the most significant factor in producing a higher Id value. The optimum condition for the highest Id value was at a channel length of 3 µm and an electrode size of 3 µm × 20 µm, with a thickness of 50 nm for the Ag electrode. The electrical measurement in both the simulation and experiment under optimal conditions showed a similar trend, and the difference between the curves was calculated to be 28.7%. Raman analyses were performed to validate the quality of TiO2-rGO.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Micromachines (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Malasia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Micromachines (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Malasia
...