Your browser doesn't support javascript.
loading
Less wear in deep-dished mobile compared to fixed bearing total knee arthroplasty of the same design at 5-year follow-up: a randomised controlled model-based Roentgen stereophotogrammetric analysis trial.
Kalaai, S; Most, J; van Dun, B; Kaptein, B L; Tilman, P B J; Boonen, B; Schotanus, M G M.
Afiliación
  • Kalaai S; Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands. soufyankalaai@hotmail.com.
  • Most J; Department of Surgery, Diakonessenhuis Utrecht, Utrecht, The Netherlands. soufyankalaai@hotmail.com.
  • van Dun B; Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.
  • Kaptein BL; School of Care and Public Health Research Institute, Faculty of Health, Medicine and Life Sciences, Maastricht University Medical Center+, Maastricht, The Netherlands.
  • Tilman PBJ; Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.
  • Boonen B; Department of Orthopaedic Surgery and Traumatology, Imelda Hospital, Bonheiden, Belgium.
  • Schotanus MGM; Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 5137-5144, 2023 Nov.
Article en En | MEDLINE | ID: mdl-37796308
PURPOSE: The aim of this prospective randomised controlled study was to compare wear characteristics and functional outcome between deep-dished mobile bearing (MB) and fixed bearing (FB) cemented total knee arthroplasty (TKA). We hypothesised that deep-dished MB reduces polyethylene wear and improves patient-reported outcome measures. METHODS: A total of 50 patients were randomised to receive a MB or FB tibia component of the same cemented TKA design. Patients were evaluated over a 5-year follow-up period. Medial and lateral wear were assessed using model-based Roentgen Stereophotogrammetric Analysis (RSA) and compared with the direct postoperative minimal joint space measurement. Functional outcome was assessed by the clinician-derived KSS and OKS, WOMAC, LEAS, and FJS-12. All data were derived using a general linear mixed model. RESULTS: At 5-year follow-up, decreased wear in the MB compared to the FB group was observed on the lateral side (0.07 ± 0.17 mm, p = 0.026), but not on the medial side (0.31 ± 0.055 mm, p = 0.665). Functional outcomes improved with a statistical significant effect over time, with no significant differences between groups (all p > 0.17). CONCLUSION: This model-based RSA study with 5-year follow-up showed that cemented deep-dished MB reduced lateral polyethylene wear as compared to FB in a single TKA system, whilst clinical outcomes were comparable. Longer follow-up is needed to establish clinical implications of these altered wear patterns and determine type of wear. LEVEL OF EVIDENCE: Level 1 randomised controlled trial.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Prótesis de la Rodilla Tipo de estudio: Clinical_trials / Prognostic_studies Aspecto: Patient_preference Límite: Humans Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Asunto de la revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Prótesis de la Rodilla Tipo de estudio: Clinical_trials / Prognostic_studies Aspecto: Patient_preference Límite: Humans Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Asunto de la revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos
...