Your browser doesn't support javascript.
loading
Sensitivity of simulated knee joint mechanics to selected human and bovine fibril-reinforced poroelastic material properties.
Jahangir, Sana; Esrafilian, Amir; Ebrahimi, Mohammadhossein; Stenroth, Lauri; Alkjær, Tine; Henriksen, Marius; Englund, Martin; Mononen, Mika E; Korhonen, Rami K; Tanska, Petri.
Afiliación
  • Jahangir S; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland. Electronic address: sana.jahangir@uef.fi.
  • Esrafilian A; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
  • Ebrahimi M; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
  • Stenroth L; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland; Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Alkjær T; Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark; The Parker Institute, Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark.
  • Henriksen M; The Parker Institute, Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark.
  • Englund M; Department of Clinical Sciences, Lund University, Lund, Sweden.
  • Mononen ME; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
  • Korhonen RK; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
  • Tanska P; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland. Electronic address: petri.tanska@uef.fi.
J Biomech ; 160: 111800, 2023 Sep 14.
Article en En | MEDLINE | ID: mdl-37797566
ABSTRACT
Fibril-reinforced poroviscoelastic material models are considered state-of-the-art in modeling articular cartilage biomechanics. Yet, cartilage material parameters are often based on bovine tissue properties in computational knee joint models, although bovine properties are distinctly different from those of humans. Thus, we aimed to investigate how cartilage mechanical responses are affected in the knee joint model during walking when fibril-reinforced poroviscoelastic properties of cartilage are based on human data instead of bovine. We constructed a finite element knee joint model in which tibial and femoral cartilages were modeled as fibril-reinforced poroviscoelastic material using either human or bovine data. Joint loading was based on subject-specific gait data. The resulting mechanical responses of knee cartilage were compared between the knee joint models with human or bovine fibril-reinforced poroviscoelastic cartilage properties. Furthermore, we conducted a sensitivity analysis to determine which fibril-reinforced poroviscoelastic material parameters have the greatest impact on cartilage mechanical responses in the knee joint during walking. In general, bovine cartilage properties yielded greater maximum principal stresses and fluid pressures (both up to 30%) when compared to the human cartilage properties during the loading response in both femoral and tibial cartilage sites. Cartilage mechanical responses were very sensitive to the collagen fibril-related material parameter variations during walking while they were unresponsive to proteoglycan matrix or fluid flow-related material parameter variations. Taken together, human cartilage material properties should be accounted for when the goal is to compare absolute mechanical responses of knee joint cartilage as bovine material parameters lead to substantially different cartilage mechanical responses.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Biomech Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Biomech Año: 2023 Tipo del documento: Article
...