A Theoretical Study on the Spatiotemporal Variation in the Temperature Field in Linings of High-Water-Temperature Tunnels.
Huang, Mingli; Huang, Meng; Li, Jiacheng; Qian, Yuan.
Afiliación
  • Huang M; School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China.
  • Huang M; School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China.
  • Li J; School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China.
  • Qian Y; College of Civil Engineering, Tongji University, Shanghai 200092, China.
Materials (Basel) ; 16(22)2023 Nov 13.
Article en En | MEDLINE | ID: mdl-38005069
ABSTRACT
On the basis of the theory of unsteady heat conduction, discrete equations for the unsteady temperature field in the secondary linings of high-water-temperature tunnels when considering the hydration heat of lining concrete were derived and established. Spatiotemporal variation in the temperature field of tunnel linings was revealed through the analysis of numerical examples. Research demonstrates that the temperature of the secondary lining within a thickness range of approximately 15 cm near the tunnel clearance decreases sharply under the condition that the lining thickness is 35 cm. The higher the temperature on the lining's outer surface, the more drastically the lining temperature decreases. When considering the hydration heat of lining concrete, the lining temperature increases to a certain extent after a sudden drop, reaching stability after approximately 20 h, and the lining temperature is approximately 1-2 °C higher than that without taking concrete hydration heat into account. The temperature difference between the tunnel lining's core and its inner and outer surfaces is positively and negatively correlated with the temperature of the secondary lining's outer surface, respectively. When the temperature of the secondary lining's outer surface is not higher than 65 °C, the temperature difference between the tunnel lining's core and its inner and outer surfaces is less than 20 °C. Conversely, it partially or completely exceeds 20 °C, in which case an insulation method is recommended to utilize to prevent thermal cracks in secondary linings triggered via a high temperature difference.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2023 Tipo del documento: Article País de afiliación: China
...