Stimulation Crosstalk Between Cochlear And Vestibular Spaces During Cochlear Electrical Stimulation.
de Miguel, Ángel Ramos; Rodriguez Montesdeoca, Isaura; Falcón González, Juan Carlos; Borkoski Barreiro, Silvia; Zarowski, Andrzej; Sluydts, Morgana; Falcón Benitez, Nadia; Ramos Macias, Angel.
Afiliación
  • de Miguel ÁR; Hearing and Balance Laboratory, University of Las Palmas de Gran Canaria, Las Palmas, Spain.
  • Rodriguez Montesdeoca I; Department of Otolaryngology, and Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, Las Palmas, Spain.
  • Falcón González JC; Department of Otolaryngology, and Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, Las Palmas, Spain.
  • Borkoski Barreiro S; Department of Otolaryngology, and Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, Las Palmas, Spain.
  • Zarowski A; European Institute for Otorhinolaryngology, GZA Hospitals Antwerp, Wilrijk, Belgium.
  • Sluydts M; European Institute for Otorhinolaryngology, GZA Hospitals Antwerp. Lab for Equilibrium Investigations and Aerospace, University of Antwerp, Wilrijk, Belgium.
  • Falcón Benitez N; Hearing and Balance Laboratory, University of Las Palmas de Gran Canaria, Las Palmas, Spain.
  • Ramos Macias A; Department of Otolaryngology, and Head and Neck Surgery, Complejo Hospitalario Universitario Insular Materno Infantil de Gran Canaria, Hearing and Balance Laboratory, University of Las Palmas de Gran Canaria, Las Palmas, Spain.
Laryngoscope ; 134(5): 2349-2355, 2024 May.
Article en En | MEDLINE | ID: mdl-38010817
OBJECTIVES: Possible beneficial "crosstalk" during cochlear implant stimulation on otolith end organs has been hypothesized. The aim of this case-control study is to analyze the effect of electrical cochlear stimulation on the vestibule (otolith end-organ), when using a cochleo-vestibular implant, comparing vestibular stimulation (VI) and cochlear stimulation (CI). METHODS: Four patients with bilateral vestibulopathy were included. A double electrode array research implant was implanted in all cases. Dynamic Gait Index (DGI), VOR gain measured by using vestibular head impulse test (vHIT), acoustic cervical myogenic responses (cVEMP) recordings, and electrical cVEMP were used in all cases. Trans-impedance Matrix (TIM) analysis was used to evaluate the current flow from the cochlea to the vestibule. RESULTS: While patients did not have any clinical vestibular improvement with the CI stimulation alone, gait metrics of the patients revealed improvement when the vestibular electrode was stimulated. The average improvement in the DGI was 38% when the vestibular implant was activated, returning to the normal range in all cases. Our findings suggest that any current flow from the cochlear space to the otolith organs was insufficient for effective cross-stimulation. The functional results correlated with the data obtained in TIM analysis, confirming that there is no current flow from the cochlea to the vestibule. CONCLUSION: The only way to produce effective electrical otolith end-organ stimulation, demonstrated with this research implant, is by direct electrical stimulation of the otolith end organs. No effective cross-stimulation was found from cochlear electrode stimulation. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:2349-2355, 2024.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vestíbulo del Laberinto / Implantes Cocleares / Implantación Coclear / Potenciales Vestibulares Miogénicos Evocados Límite: Humans Idioma: En Revista: Laryngoscope Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vestíbulo del Laberinto / Implantes Cocleares / Implantación Coclear / Potenciales Vestibulares Miogénicos Evocados Límite: Humans Idioma: En Revista: Laryngoscope Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: España
...