Your browser doesn't support javascript.
loading
HPLC-LED-Induced Fluorescence Analysis of Tear Fluids: An Objective Method for Primary Open Angle Glaucoma Diagnosis.
Adigal, Sphurti S; Kuzhuppilly, Neetha I R; Hegde, Nagaraj; V R, Nidheesh; Rizvi, Alisha; John, Reena V; George, Sajan D; Kartha, Vasudevan B; Bhandary, Sulatha V; Chidangil, Santhosh.
Afiliación
  • Adigal SS; Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Kuzhuppilly NIR; Department of Ophthalmology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Hegde N; Arion, The Randstad Netherlands, Eindhoven City, the Netherlands.
  • V R N; Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Rizvi A; Department of Ophthalmology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • John RV; Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • George SD; Centre for Applied Nanosciences, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Kartha VB; Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Bhandary SV; Department of Ophthalmology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Chidangil S; Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India.
Curr Eye Res ; 49(3): 260-269, 2024 Mar.
Article en En | MEDLINE | ID: mdl-38078692
ABSTRACT

PURPOSE:

The study showcased the application of the lab-assembled HPLC-LED-IF system to analyze proteins in tear fluid samples collected from individuals diagnosed with primary open-angle glaucoma (POAG).

METHODS:

Clinical application of the said technique was evaluated by recording chromatograms of tear fluid samples from control and POAG subjects and by analyzing the protein profile using multivariate analysis. The data analysis methods involved are principal component analysis (PCA), Match/No-Match, and artificial neural network (ANN) based binary classification for disease diagnosis.

RESULTS:

Mahalanobis distance and spectral residual values calculated using a standard calibration set of clinically confirmed POAG samples for the Match/No-Match test gave 86.9% sensitivity and 81.8% specificity. ANN with leaving one out procedure has given 87.1% sensitivity and 81.8% specificity.

CONCLUSION:

The results of the study revealed that the utilization of a 278 nm LED excitation in the HPLC system offers good sensitivity for detecting proteins at low concentrations allowing to obtain reliable protein profiles for the diagnosis of POAG.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glaucoma de Ángulo Abierto Límite: Humans Idioma: En Revista: Curr Eye Res Año: 2024 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glaucoma de Ángulo Abierto Límite: Humans Idioma: En Revista: Curr Eye Res Año: 2024 Tipo del documento: Article País de afiliación: India
...