The Stapes Head Coupler-A Flexible and Safe Option for Vibroplasty.
Otol Neurotol
; 45(1): 11-17, 2024 Jan 01.
Article
en En
| MEDLINE
| ID: mdl-38085759
ABSTRACT
OBJECTIVE:
To investigate the surgical approach and the audiological outcome of a stapes head coupler in active middle ear implant surgery. STUDYDESIGN:
Retrospective data analysis.SETTING:
Tertiary referral center with a large active middle ear implant program. PATIENTS Twelve patients with active middle ear implant surgery.INTERVENTIONS:
Therapeutic surgical approach for hearing rehabilitation in human subjects. MAIN OUTCOMEMEASURES:
Auditory brainstem response, sound field thresholds, vibrogram, speech perception in the Freiburger monosyllabic word test.RESULTS:
The stapes head was attached safely in different coupling situations. Audiological outcomes were similar to the audiological performance of established vibroplasty couplers presented in the literature.CONCLUSION:
The stapes head coupler is a new and safe tool for vibroplasty with a good audiological outcome.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Prótesis Osicular
/
Perdida Auditiva Conductiva-Sensorineural Mixta
Límite:
Humans
Idioma:
En
Revista:
Otol Neurotol
Asunto de la revista:
NEUROLOGIA
/
OTORRINOLARINGOLOGIA
Año:
2024
Tipo del documento:
Article
País de afiliación: