Your browser doesn't support javascript.
loading
Complement and Non-Complement Binding Anti-HLA Antibodies Are Differentially Detected with Different Antigen Bead Assays in Renal Transplant Recipients.
Ouranos, Konstantinos; Panteli, Manolis; Petasis, Georgios; Papachristou, Marianthi; Iosifidou, Artemis Maria; Iosifidou, Myrto Aikaterini; Anastasiou, Aikaterini; Samali, Margarita; Stangou, Maria; Theodorou, Ioannis; Lioulios, Georgios; Fylaktou, Asimina.
Afiliación
  • Ouranos K; Department of Medicine, Houston Methodist Research Institute, Houston, TX 77030, USA.
  • Panteli M; School of Medicine, Aristotle University of Thessaloniki, 45636 Thessaloniki, Greece.
  • Petasis G; National Peripheral Histocompatibility Center, Department of Immunology, Hippokration Hospital, 54642 Thessaloniki, Greece.
  • Papachristou M; School of Medicine, Aristotle University of Thessaloniki, 45636 Thessaloniki, Greece.
  • Iosifidou AM; National Peripheral Histocompatibility Center, Department of Immunology, Hippokration Hospital, 54642 Thessaloniki, Greece.
  • Iosifidou MA; School of Medicine, Aristotle University of Thessaloniki, 45636 Thessaloniki, Greece.
  • Anastasiou A; School of Medicine, Aristotle University of Thessaloniki, 45636 Thessaloniki, Greece.
  • Samali M; School of Medicine, Aristotle University of Thessaloniki, 45636 Thessaloniki, Greece.
  • Stangou M; National Peripheral Histocompatibility Center, Department of Immunology, Hippokration Hospital, 54642 Thessaloniki, Greece.
  • Theodorou I; National Peripheral Histocompatibility Center, Department of Immunology, Hippokration Hospital, 54642 Thessaloniki, Greece.
  • Lioulios G; School of Medicine, Aristotle University of Thessaloniki, 45636 Thessaloniki, Greece.
  • Fylaktou A; 1st Department of Nephrology, Hippokration Hospital, 54642 Thessaloniki, Greece.
J Clin Med ; 12(24)2023 Dec 17.
Article en En | MEDLINE | ID: mdl-38137802
ABSTRACT
Two semi-quantitative, Luminex-based, single-antigen bead (SAB) assays are available to detect anti-HLA antibodies and evaluate their reactivity with complement binding. Sera from 97 patients with positive panel reactive antibody tests (>5%) were analyzed with two SAB tests, Immucor (IC) and One-Lambda (OL), for anti-HLA antibody detection and the evaluation of their complement-binding capacity. IC detected 1608/8148 (mean fluorescent intensity (MFI) 4195 (1995-11,272)) and 1136/7275 (MFI 6706 (2647-13,184)) positive anti-HLA class I and II specificities, respectively. Accordingly, OL detected 1942/8148 (MFI 6185 (2855-12,099)) and 1247/7275 (MFI 9498 (3630-17,702)) positive anti-HLA class I and II specificities, respectively. For the IC assay, 428/1608 (MFI 13,900 (9540-17,999)) and 409/1136 (MFI 11,832 (7128-16,531)) positive class I and II specificities bound C3d, respectively. Similarly, OL detected 485/1942 (MFI 15,452 (9369-23,095)) and 298/1247 (MFI18,852 (14,415-24,707)) C1q-binding class I and II specificities. OL was more sensitive in detecting class I and II anti-HLA antibodies than IC was, although there was no significant difference in the number of class II specificities per case. MFI was higher for complement vs. non-complement-binding anti-HLA antibodies in both assays. Both methods were equal in detecting complement-binding anti-HLA class I antibodies, whereas the C3d assay was more sensitive in detecting complement-binding anti-HLA class II antibodies.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos
...