Your browser doesn't support javascript.
loading
Antidromic snare technique for re-implantation of a coronary sinus lead into the same cardiac vein after transvenous lead extraction: a case report.
Kim, Juwon; Chung, Tae-Wan; Park, Seung-Jung.
Afiliación
  • Kim J; Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, South Korea.
  • Chung TW; Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, South Korea.
  • Park SJ; Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, South Korea.
Eur Heart J Case Rep ; 8(1): ytad625, 2024 Jan.
Article en En | MEDLINE | ID: mdl-38152119
ABSTRACT

Background:

After coronary sinus (CS) lead extraction in patients with cardiac resynchronization therapy (CRT), occlusion of the branch vessel from which CS lead was extracted is a major obstacle to re-implantation, particularly if that vessel is the only optimal vessel for resynchronization. Case

summary:

A 75-year-old female who underwent CRT implantation 11 years prior presented with worsening dyspnoea, right ventricle-only pacing rhythm, and increased CS lead pacing threshold. Because she was a CRT responder, we decided to replace the malfunctioning CS lead. After successful extraction, the vessel from which CS lead was extracted was not visualized, and guidewire re-insertion attempts failed. No other branch vessels suitable for re-implantation were observed. Fortunately, distal portion of the target vessel was viewed by a retrograde flow of contrast. A guidewire was advanced retrograde into the target vein via a connecting vessel, and the distal end of the guidewire was snared around CS ostium and then pulled out of the sheath. A new CS lead was inserted through the distal end of the guidewire and successfully implanted antegrade into the same target vein using a veno-venous loop of the guidewire ('anti-dromic snare technique'). The patient was discharged 2 days after the procedure without complications.

Discussion:

Antegrade re-implantation of CS lead may not be possible after extracting CS leads with long dwell times, possibly due to extraction-induced vessel occlusion. If the occluded vessel is the only proper vessel for CS lead re-implantation, the anti-dromic snare technique could be a safe and effective bail-out strategy.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Eur Heart J Case Rep Año: 2024 Tipo del documento: Article País de afiliación: Corea del Sur

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Eur Heart J Case Rep Año: 2024 Tipo del documento: Article País de afiliación: Corea del Sur
...