Your browser doesn't support javascript.
loading
Secondary retensioning of a tether-based device for transapical transcatheter mitral valve implantation.
Beyer, Martin; Muller, David; De Marco, Federico; Badhwar, Vinay; Obadia, Jean-Francois; Praz, Fabien; Modine, Thomas; Tonino, Pim; Dahle, Gry; Cerillo, Alfredo; Ludwig, Sebastian; Conradi, Lenard.
Afiliación
  • Beyer M; Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, Hamburg, Germany.
  • Muller D; Cardiology Department, St Vincent's Hospital, Sydney, NSW, Australia.
  • De Marco F; Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, Milan, Italy.
  • Badhwar V; Department of Cardiovascular and Thoracic Surgery, West Virginia University, Morgantown, WV, USA.
  • Obadia JF; Department of Cardiac Surgery, "Louis Pradel" Cardiologic Hospital, Lyon, France.
  • Praz F; Department of Cardiology, University Hospital Bern, University of Bern, Bern, Switzerland.
  • Modine T; Department of Cardiology and Cardiovascular Surgery, Heart Valve Center, Institut Cœur Poumon CHU de Bordeaux, Bordeaux, France.
  • Tonino P; Department of Cardiology, Catharina Hospital, Eindhoven, Netherlands.
  • Dahle G; Department of Cardiothoracic Surgery, Oslo University Hospital, Norway.
  • Cerillo A; Department of Cardiac Surgery, Careggi University Hospital, Florence, Italy.
  • Ludwig S; Department of Cardiology, University Heart & Vascular Center Hamburg, Hamburg, Germany.
  • Conradi L; German Center for Cardiovascular Research: DZHK, Partner Site Hamburg/Kiel/Lübeck, Germany.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Article en En | MEDLINE | ID: mdl-38152923
ABSTRACT

OBJECTIVES:

Relevant paravalvular leakage (PVL) due to prosthesis dislodgement is a rare but potentially severe complication after transcatheter mitral valve implantation (TMVI). Due to the epicardial anchoring mechanism of the Tendyne® TMVI system, repositioning of the valve stent may be possible by retensioning of the tether. This multicentre study aimed to investigate the procedural and short-term safety as well as efficacy of retensioning manoeuvres.

METHODS:

From 2017 to 2021, N = 18 patients who underwent secondary tether retensioning were identified. Baseline, procedural and follow-up data were available from N = 11 patients and analysed according to the Mitral Valve Research Consortium definitions. Continuous variables are shown as median with interquartile range.

RESULTS:

All patients [age 75 years (73.5, 85.0), 64% male (N = 7), EuroSCORE II 6.2% (5.8, 11.6)] presented with post-procedural PVL [63.6% (N = 7) with PVL ≥3+]. Of these, 54% (N = 6) showed signs of haemolysis. The majority were severely symptomatic [New York Heart Association ≥III (91%, N = 10)]. Procedural outcomes revealed no acute complications and no mortality. At discharge, PVL was completely eliminated in 91% (N = 10) of patients with 1 case of remaining moderate PVL. At 30 days, Mitral Valve Research Consortium device success was achieved in 82% (N = 9) of patients. Two patients required open surgical mitral valve replacement due to persistent and recurrent PVL. In 89% (N = 8) of patients with successful retensioning procedure, New York Heart Association class was I/II. There was no 30-day mortality.

CONCLUSIONS:

This multicentre study demonstrates technical feasibility, procedural safety and acute efficacy of retensioning procedures in the majority of patients. The potential to retension the tether in transapical TMVI may provide additional management advantages in populations at high surgical risk.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_cardiovascular_diseases Asunto principal: Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Insuficiencia de la Válvula Mitral Límite: Aged / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Eur J Cardiothorac Surg Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_cardiovascular_diseases Asunto principal: Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Insuficiencia de la Válvula Mitral Límite: Aged / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Eur J Cardiothorac Surg Asunto de la revista: CARDIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Alemania
...