Your browser doesn't support javascript.
loading
Mid-term efficacy of castor stent and in situ fenestration stent in the treatment of type B aortic dissection involving the left subclavian artery: A retrospective single-center study.
Wu, Qingsong; Xie, Lin-Feng; Li, Huangwei; Shen, Yue; Qiu, Zhihuang; Chen, Liangwan.
Afiliación
  • Wu Q; Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, China.
  • Xie LF; Cardiothoracic surgery, Fujian Medical University, Fuzhou, Fujian, China.
  • Li H; Key Laboratory of Cardio-Thoracic Surgery (Fujian Medical University), Fujian Province University, Fuzhou, Fujian, China.
  • Shen Y; Cardiothoracic surgery, Fujian Medical University, Fuzhou, Fujian, China.
  • Qiu Z; Cardiothoracic surgery, Fujian Medical University, Fuzhou, Fujian, China.
  • Chen L; Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, Fujian, China.
J Clin Hypertens (Greenwich) ; 26(1): 63-70, 2024 01.
Article en En | MEDLINE | ID: mdl-38155479
ABSTRACT
To evaluate the midterm efficacy of the Castor stent (CS) versus in situ fenestration (ISF) for reconstructing the left subclavian artery (LSA) in patients with type B aortic dissection (TBAD). Between July 2017 and July 2022, a total of 247 patients with TBAD were enrolled. One hundred thirty-seven patients were treated using CSs (group A), while the remaining 110 patients received ISFs (group B). Data of the two groups were retrospectively analyzed. The success rates of surgery were 99.3% and 95.5% in groups A and B (p = .053), There were no deaths during hospitalization. During surgery, group B showed a longer surgical duration [68.0 (66.0, 77.0) vs. 62.0 (59.0, 66.0) min, p < .001] and intraoperative fluoroscopy time [18.0 (16.0, 20.0) vs. 16.0 (14.0, 18.0) min, p < .001] than group A. The follow-up duration was similar for both groups (44.0 vs. 43.0 months, p = .877), and no patient died. Stent-related complications were significantly lower in group A than in group B (1.5% vs. 8.4%, p = .009). Group A had fewer instances entry flow (0.7% vs. 4.7%, p = .048) and stent stenosis (0.7% vs. 2.8%, p = .206) than group B. All reintervention cases (4.7%) were from group B (p = .011). The rate of false aortic lumen thrombosis was significantly higher in group A than in group B (84.6% vs. 72.9%, p = .024). Both CSs and ISFs are evidently safe, feasible, and effective in achieving positive early outcomes in patients undergoing treatment for TBAD. Notably, at midterm follow-up, CSs appeared to be superior to ISF in terms of reducing stent-related complications and minimizing the need for reintervention.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_arterial_hypertension / 6_cardiovascular_diseases Asunto principal: Trombosis / Aneurisma de la Aorta Torácica / Implantación de Prótesis Vascular / Hipertensión / Disección Aórtica Límite: Humans Idioma: En Revista: J Clin Hypertens (Greenwich) Asunto de la revista: ANGIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 6_ODS3_enfermedades_notrasmisibles Problema de salud: 6_arterial_hypertension / 6_cardiovascular_diseases Asunto principal: Trombosis / Aneurisma de la Aorta Torácica / Implantación de Prótesis Vascular / Hipertensión / Disección Aórtica Límite: Humans Idioma: En Revista: J Clin Hypertens (Greenwich) Asunto de la revista: ANGIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China
...