Measurement of urinary exosomal phospholipase A2 receptor is a sensitive method for diagnosis of PLA2R-associated membranous nephropathy.
Wang, Bin; Fu, Yu-Qi; Xie, Li-Jun; Cao, Jin-Yuan; Yang, Min; Li, Min; Chen, Tian-Lei; Zhang, Xiao-Liang; Luo, Qian; Lv, Lin-Li; Liu, Bi-Cheng.
Afiliación
  • Wang B; Institute of Nephrology, Zhong Da Hospital, Southeast University School of Medicine, Nanjing, Jiangsu, China.
  • Fu YQ; Institute of Nephrology, Zhong Da Hospital, Southeast University School of Medicine, Nanjing, Jiangsu, China.
  • Xie LJ; Institute of Nephrology, Zhong Da Hospital, Southeast University School of Medicine, Nanjing, Jiangsu, China.
  • Cao JY; Institute of Nephrology, Zhong Da Hospital, Southeast University School of Medicine, Nanjing, Jiangsu, China.
  • Yang M; Department of Nephrology, Fifth Affiliated Hospital of Nantong University, Taizhou, China.
  • Li M; Department of Nephrology, the Third Affiliated Hospital of Soochow University, Changzhou, China.
  • Chen TL; Department of Nephrology, the Third Affiliated Hospital of Soochow University, Changzhou, China.
  • Zhang XL; Department of Nephrology, the Third Affiliated Hospital of Soochow University, Changzhou, China.
  • Luo Q; Institute of Nephrology, Zhong Da Hospital, Southeast University School of Medicine, Nanjing, Jiangsu, China.
  • Lv LL; Bionic Sensing and Intelligence Center, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Liu BC; Institute of Nephrology, Zhong Da Hospital, Southeast University School of Medicine, Nanjing, Jiangsu, China.
Clin Kidney J ; 17(1): sfad191, 2024 Jan.
Article en En | MEDLINE | ID: mdl-38186888
ABSTRACT

Background:

The discovery of phospholipase A2 receptor (PLA2R) and its antibody (aPLA2Rab) has paved the way for diagnosing PLA2R-associated membranous nephropathy (PLA2R-MN) with a high specificity of 98%. However, the sensitivity was only 40% to 83.9%, and there is ongoing discussion around determining the optimal threshold for diagnosis. Recent advancements in the use of exosomes, a novel form of "liquid biopsy," have shown great promise in identifying markers for various medical conditions.

Methods:

Protein mass spectrometry and western blot were applied to verify the existence of PLA2R antigen in the urine exosome. We then evaluated the efficacy of urinary exosomal PLA2R antigen alone or combined with serum aPLA2Rab level to diagnose PLA2R-MN.

Results:

The urinary exosomes contained a high abundance of PLA2R antigen as evidenced by protein mass spectrometry and western blot in 85 PLA2R-MN patients vs the disease controls (14 secondary MN patients, 22 non-MN patients and 4 PLA2R-negative MN patients) and 20 healthy controls. Of note, urinary exosomal PLA2R antigen abundance also had a good consistency with the PLA2R antigen level in the renal specimens of PLA2R-MN patients. The sensitivity of urinary exosomal PLA2R for diagnosing PLA2R-MN reached 95.4%, whereas the specificity was 63.3%. Combining detection of the urinary exosomal PLA2R and serum aPLA2Rab could develop a more sensitive diagnostic method for PLA2R-MN, especially for patients with serum aPLA2Rab ranging from 2 to 20 RU/mL.

Conclusions:

Measurement of urinary exosomal PLA2R could be a sensitive method for the diagnosis of PLA2R-MN.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Risk_factors_studies Idioma: En Revista: Clin Kidney J Año: 2024 Tipo del documento: Article País de afiliación: China