Your browser doesn't support javascript.
loading
Assessment of blood-brain barrier leakage and brain oxygenation in Connexin-32 knockout mice with systemic neuroinflammation using pulse electron paramagnetic resonance imaging techniques.
Epel, Boris; Viswakarma, Navin; Hameed, Safa; Freidin, Mona M; Abrams, Charles K; Kotecha, Mrignayani.
Afiliación
  • Epel B; Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
  • Viswakarma N; Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois, USA.
  • Hameed S; Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
  • Freidin MM; Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
  • Abrams CK; Department of Neurology and Rehabilitation, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Kotecha M; Department of Neurology and Rehabilitation, University of Illinois at Chicago, Chicago, Illinois, USA.
Magn Reson Med ; 91(6): 2519-2531, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38193348
ABSTRACT

PURPOSE:

The determination of blood-brain barrier (BBB) integrity and partial pressure of oxygen (pO2) in the brain is of substantial interest in several neurological applications. This study aimed to assess the feasibility of using trityl OX071-based pulse electron paramagnetic resonance imaging (pEPRI) to provide a quantitative estimate of BBB integrity and pO2 maps in mouse brains as a function of neuroinflammatory disease progression.

METHODS:

Five Connexin-32 (Cx32)-knockout (KO) mice were injected with lipopolysaccharide to induce neuroinflammation for imaging. Three wild-type mice were also used to optimize the imaging procedure and as control animals. An additional seven Cx32-KO mice were used to establish the BBB leakage of trityl using the colorimetric assay. All pEPRI experiments were performed using a preclinical instrument, JIVA-25 (25 mT/720 MHz), at times t = 0, 4, and 6 h following lipopolysaccharide injection. Two pEPRI imaging techniques were used (a) single-point imaging for obtaining spatial maps to outline the brain and calculate BBB leakage using the signal amplitude, and (b) inversion-recovery electron spin echo for obtaining pO2 maps.

RESULTS:

A statistically significant change in BBB leakage was found using pEPRI with the progression of inflammation in Cx32 KO animals. However, the change in pO2 values with the progression of inflammation for these animals was not statistically significant.

CONCLUSIONS:

For the first time, we show the ability of pEPRI to provide pO2 maps in mouse brains noninvasively, along with a quantitative assessment of BBB leakage. We expect this study to open new queries from the field to explore the pathology of many neurological diseases and provide a path to new treatments.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Barrera Hematoencefálica / Enfermedades Neuroinflamatorias Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Barrera Hematoencefálica / Enfermedades Neuroinflamatorias Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos
...