Your browser doesn't support javascript.
loading
Sensitive electrochemiluminescence immunosensor based on a novel luminescent europium metal-organic framework and antenna effect for detecting pro-gastrin-releasing peptide.
Xu, Lixin; Hu, Shenglan; Yang, Juan; Wang, Na; Wu, Yusheng; Deng, Biyang.
Afiliación
  • Xu L; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China.
  • Hu S; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China.
  • Yang J; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China.
  • Wang N; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China.
  • Wu Y; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China.
  • Deng B; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin, 541004, China. Electronic address: dengby16@163.com.
Talanta ; 270: 125644, 2024 Apr 01.
Article en En | MEDLINE | ID: mdl-38218005
ABSTRACT
Sensitive detection of pro-gastrin-releasing peptide (Pro-GRP) is crucial because it is a highly sensitive and specific tumor marker for small cell lung cancer. Herein, we synthesized an efficient luminescent europium metal-organic framework and developed a sandwich ECL immunosensor for the sensitive detection of Pro-GRP, which used Eu3+ as the central ion and 2,4,6-tri (4-carboxyphenyl)-1,3,5-triazine (H3TATB) as the organic ligand. H3TATB acted as a strong absorbing reagent and transferred its energy to Eu3+ via the antenna effect to enhance the ECL response signal of Eu3+. As per calculations, the ECL efficiency of Eu-TATB, which was a promising ECL luminophore, was up to 130 %. The Cu2O cube worked as a substrate to assist the electron transfer and was used as a co-reaction accelerator to catalyze S2O82- to produce more SO4•- and then enhance the ECL intensity of Eu-TATB. Under optimal experimental conditions, the ECL immunosensor had a linear range of 5 fg mL-1-50 ng mL-1 for detecting Pro-GRP with a detection limit of 1.6 fg mL-1; moreover, it demonstrated excellent stability and specificity and has been successfully applied for detecting Pro-GRP in the human serum.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Nanopartículas del Metal / Estructuras Metalorgánicas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Nanopartículas del Metal / Estructuras Metalorgánicas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article País de afiliación: China
...