Efficacy and safety of a home-use handheld multi-energy-based device for skin rejuvenation: clinical, ex vivo, and histological studies.
Choi, Sooyeon; Kim, Jemin; Lee, Young In; Lee, Sang Gyu; Jung, Inhee; Suk, Jangmi; Lee, Ju Hee.
Afiliación
  • Choi S; Department of Dermatology & Cutaneous Biology Research Institute, Yonsei University College of Medicine, 50-1 Yonsei Ro, Seodaemun-Gu, Seoul, 03722, Korea.
  • Kim J; Department of Dermatology & Cutaneous Biology Research Institute, Yonsei University College of Medicine, 50-1 Yonsei Ro, Seodaemun-Gu, Seoul, 03722, Korea.
  • Lee YI; Scar Laser and Plastic Surgery Center, Yonsei Cancer Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Lee SG; Department of Dermatology & Cutaneous Biology Research Institute, Yonsei University College of Medicine, 50-1 Yonsei Ro, Seodaemun-Gu, Seoul, 03722, Korea.
  • Jung I; Scar Laser and Plastic Surgery Center, Yonsei Cancer Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Suk J; Department of Dermatology & Cutaneous Biology Research Institute, Yonsei University College of Medicine, 50-1 Yonsei Ro, Seodaemun-Gu, Seoul, 03722, Korea.
  • Lee JH; Global Medical Research Center, Seoul, Korea.
Lasers Med Sci ; 39(1): 38, 2024 Jan 18.
Article en En | MEDLINE | ID: mdl-38236440
ABSTRACT
Alongside increases in the average lifespan and a growing interest in anti-aging remedies, the demand for at-home skincare devices is rapidly expanding in the cosmetic market. This study aimed to assess the safety and efficacy of a novel home-use handheld multi-energy-based device for skin rejuvenation that simultaneously emits low level light, low-dose radiofrequency, low-energy microcurrent, and low-intensity ultrasonic wave. This prospective, randomized, split-face clinical trial enrolled 36 healthy Korean women. After 8 weeks of device use, parameters associated with skin aging were assessed. Additionally, a preliminary ex vivo study and skin biopsy following device use were performed to confirm safety and efficiency of the device. Parameters associated with skin aging including skin hydration, elasticity, roughness, skin pore size, and eye wrinkle volume showed significant improvements after 8 weeks of the device use, relative to baseline measurements and the control side. No adverse effects were observed during the follow-up period. Results of ex vivo and in vivo skin tissue studies correlated with clinical findings, which showed an increase in the expression of type 1 collagen and a decrease in the expression of matrix metalloproteinase-1, which is related to the skin aging phenotype. The expression of loricrin and involucrin, major components of the epidermal skin barrier, also increased after the use of the device. Multi-energy-based device is effective for skin rejuvenation and tolerable, without any considerable adverse effects.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rejuvenecimiento / Piel Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Laser in medical science / Lasers Med Sci / Lasers med. sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rejuvenecimiento / Piel Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Laser in medical science / Lasers Med Sci / Lasers med. sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2024 Tipo del documento: Article
...