Your browser doesn't support javascript.
loading
The role of wearable home blood pressure monitoring in detecting out-of-office control status.
Pan, Heng-Yu; Lee, Chih-Kuo; Liu, Tzu-Yao; Lee, Guan-Wei; Chen, Chiao-Wei; Wang, Tzung-Dau.
Afiliación
  • Pan HY; Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu City, Taiwan.
  • Lee CK; Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu City, Taiwan.
  • Liu TY; Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu City, Taiwan.
  • Lee GW; Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu City, Taiwan.
  • Chen CW; Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu City, Taiwan.
  • Wang TD; Cardiovascular Center and Divisions of Cardiology and Hospital Medicine, Department of Internal Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan. tdwang@ntu.edu.tw.
Hypertens Res ; 47(4): 1033-1041, 2024 Apr.
Article en En | MEDLINE | ID: mdl-38242946
ABSTRACT
Ambulatory blood pressure (ABP) and home blood pressure (HBP) monitoring is currently recommended for management of hypertension. Nonetheless, traditional HBP protocols could overlook diurnal fluctuations, which could also be linked with adverse cardiovascular outcomes. In this observational study, we studied among a group of treated hypertensive patients (N = 62, age 52.4 ± 10.4 years) by using out-of-office ABP and wearable HBP. They received one session of 24-h ABP measurement with an oscillometric upper-arm monitor, and totally three sessions of 7-day/6-time-daily wearable HBP measurement separated in each month with HeartGuide. Controlled hypertension is defined as an average BP <130/80 mmHg for both daytime ABP and HBP. There was substantial reliability (intraclass correlation coefficient, ICC 0.883-0.911) and good reproducibility (Cohen's kappa = 0.600) for wearable HBP measurement, especially before breakfast and after dinner. Among all patients, 27.4% had both uncontrolled HBP and ABP, 30.6% had uncontrolled HBP only, while 6.5% had uncontrolled ABP only. Female gender and increased numbers of anti-hypertensive agents are correlated with controlled hypertension. Patients with uncontrolled hypertension had a significantly higher maximal daytime blood pressure, which was previously signified as an imperial marker for cardiovascular risk. In conclusion, wearable HBP monitoring in accordance with a dedicated daily-living schedule results in good reliability and reproducibility. Patients with an uncontrolled wearable HBP should benefit from repeated HBP or ABP measurement for risk stratification.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Dispositivos Electrónicos Vestibles / Hipertensión Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Hypertens Res Asunto de la revista: ANGIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Dispositivos Electrónicos Vestibles / Hipertensión Tipo de estudio: Observational_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Hypertens Res Asunto de la revista: ANGIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Taiwán
...