Your browser doesn't support javascript.
loading
Differences in kinematic parameters during gait between the patients with knee osteoarthritis and healthy controls using an insole with a single inertial measurement unit: A case-control study.
Yaguchi, Haruki; Honda, Keita; Sekiguchi, Yusuke; Huang, Chenhui; Fukushi, Kenichiro; Wang, Zhenwei; Nakahara, Kentaro; Kamimura, Masayuki; Aki, Takashi; Ogura, Ken; Izumi, Shin-Ichi.
Afiliación
  • Yaguchi H; Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan. Electronic address: haruki.yaguchi.c4@tohoku.ac.jp.
  • Honda K; Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan.
  • Sekiguchi Y; Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan.
  • Huang C; Biometrics Research Laboratories, NEC Corporation, 1131, Hinode, Abiko, Chiba 270-1198, Japan.
  • Fukushi K; Biometrics Research Laboratories, NEC Corporation, 1131, Hinode, Abiko, Chiba 270-1198, Japan.
  • Wang Z; Biometrics Research Laboratories, NEC Corporation, 1131, Hinode, Abiko, Chiba 270-1198, Japan.
  • Nakahara K; Biometrics Research Laboratories, NEC Corporation, 1131, Hinode, Abiko, Chiba 270-1198, Japan.
  • Kamimura M; Department of Orthopaedic Surgery, Tohoku University School of Medicine, 2-1, Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan.
  • Aki T; Department of Orthopaedic Surgery, Tohoku University School of Medicine, 2-1, Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan.
  • Ogura K; Ogura Orthopaedic Clinic, 1-6-10 Kamisugi, Aobaku, 980-0011 Sendai, Japan.
  • Izumi SI; Department of Physical Medicine and Rehabilitation, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan; Graduate School of Biomedical Engineering, Tohoku University, 2-1, Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan.
Clin Biomech (Bristol, Avon) ; 112: 106191, 2024 02.
Article en En | MEDLINE | ID: mdl-38301535
ABSTRACT

BACKGROUND:

An inertial measurement unit is small and lightweight, allowing patient measurements without physical constraints. This study aimed to determine the differences in kinematic parameters during gait using an insole with a single inertial measurement unit in healthy controls and on both sides in patients with knee osteoarthritis.

METHODS:

Twenty patients with knee osteoarthritis and 13 age-matched controls were included in this study. The participants walked at a self-selected speed and foot kinematics were measured during gait using an insole with a single inertial measurement unit. The right side of the healthy controls and both the affected and contralateral sides of patients with KOA were analyzed separately.

FINDINGS:

The foot extension angular velocity at toe-off was significantly reduced on the affected side than on the contralateral side (P < 0.001) and in healthy controls (P < 0.001). During the swing phase, foot posterior-anterior acceleration was significantly lower on the affected side than on the healthy controls (P = 0.005). Furthermore, despite a decrease in walking speed, foot superior-inferior acceleration at initial contact in patients was significantly lower on the contralateral side than in healthy controls (P = 0.0167), but not on the affected side (P = 0.344).

INTERPRETATION:

An insole with a single inertial measurement unit can detect differences in foot kinematics during gait between healthy controls and patients with knee osteoarthritis. Our findings indicate that patients with knee osteoarthritis exhibit dysfunction of push-off at toe-off and shock absorption at initial contact on the affected side.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_acesso_equitativo_servicos Asunto principal: Osteoartritis de la Rodilla Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Clin Biomech (Bristol, Avon) Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_acesso_equitativo_servicos Asunto principal: Osteoartritis de la Rodilla Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Clin Biomech (Bristol, Avon) Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2024 Tipo del documento: Article
...