Increased Attenuation of Intestinal Contents at CT Indicates Bowel Necrosis in Closed-Loop Small Bowel Obstruction.
Radiology
; 310(2): e231710, 2024 02.
Article
en En
| MEDLINE
| ID: mdl-38319165
ABSTRACT
Background Preoperative recognition of irreversible bowel necrosis is important, as it provides valuable guidance for surgical strategy selection but also may inform perioperative risk assessment and communication. Few studies have focused on the association between CT signs and bowel necrosis. Purpose To assess the diagnostic accuracy of CT signs to predict bowel necrosis in patients with closed-loop small bowel obstruction (CL-SBO). Materials and Methods This retrospective single-center study included patients who were surgically confirmed to have CL-SBO caused by adhesion or internal hernia between January 2016 and May 2022. Necrosis was determined based on surgical exploration and postoperative pathologic examination. Two radiologists independently reviewed CT signs by both subjective visual assessment and objective measurement. Disagreements were resolved in consensus with a third gastrointestinal radiologist. Univariable and multivariable analyses were used to assess the association between CT signs and bowel necrosis, and Cohen κ was used to assess interobserver agreement. Sensitivity and specificity were calculated for each CT sign. Results This study included 145 patients 61 (42.1%) in the necrotic group (median age, 62 years [IQR, 51-71.5 years]; 37 [60.7%] women) and 84 (57.9%) in the nonnecrotic group (median age, 61.5 years [IQR, 51-68.8 years]; 51 [60.7%] women). Univariable analysis and multivariable analysis showed that increased attenuation of intestinal contents and increased attenuation of intestinal wall were independent predictors for bowel necrosis (odds ratio = 45.3 and 15.1; P = .001 and P < .001, respectively). Increased attenuation of intestinal contents and increased attenuation of intestinal wall had similar sensitivity (64% and 67%, respectively) and specificity (99% and 92%, respectively) for predicting bowel necrosis. However, interobserver agreement was better for assessing the contents than the wall (κ = 0.84 and 0.59, respectively). Conclusion Increased attenuation of intestinal contents was a highly specific CT sign with good reproducibility to predict bowel necrosis in CL-SBO. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Taourel and Zins in this issue.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Contenido Digestivo
/
Obstrucción Intestinal
Tipo de estudio:
Guideline
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Radiology
Año:
2024
Tipo del documento:
Article