Your browser doesn't support javascript.
loading
A comparative study of stereopsis measurements: analyzing natural conditions versus dichoptic presentation using smartphones and ultraviolet printer technology.
Liu, Lu; Liu, Jiang; Xu, Lingxian; Zhao, Lingzhi; Wu, Huang.
Afiliación
  • Liu L; Department of Optometry, The Second Hospital of Jilin University, Changchun, China.
  • Liu J; Department of Optometry, The Second Hospital of Jilin University, Changchun, China.
  • Xu L; Department of Optometry, The Second Hospital of Jilin University, Changchun, China.
  • Zhao L; Department of Optometry, The Second Hospital of Jilin University, Changchun, China.
  • Wu H; Department of Optometry, The Second Hospital of Jilin University, Changchun, China.
PeerJ ; 12: e16941, 2024.
Article en En | MEDLINE | ID: mdl-38361768
ABSTRACT

Background:

Accurate differentiation between stereopsis assessments in the natural and dichoptic presentation states has proven challenging with commercial stereopsis measurement tools. This study proposes a novel method to delineate these differences more precisely.

Methods:

We instituted two stereopsis test systems predicated on a pair of 4K smartphones and a modified Frisby Near Stereotest (FNS) version. Stereoacuity was evaluated both in the natural environment state (via the modified FNS) and the dichoptic state (via smartphones). Thirty subjects aged 20 to 28 years participated in the study with the best-corrected visual acuity (VA) of each eye no less than 0 logMAR and stereoauity of no worse than 40″. Varying degrees of monocular VA loss were induced using the fogging method, while this study does not explore conditions where the VA of both eyes is worse than 0 logMAR.

Results:

When the VA difference between the two eyes did not exceed 0.2 logMAR, the modified FNS produced lower stereoacuity values compared to the 4K smartphones (Wilcoxon signed-rank test difference = 0 logMAR, Z = -3.879, P < 0.001; difference = 0.1 logMAR, Z = -3.478, P = 0.001; difference = 0.2 logMAR, Z = -3.977, P < 0.001). Conversely, no significant differences were observed when the binocular vision difference exceeded 0.2 logMAR (difference = 0.3 logMAR, Z = -1.880, P = 0.060; difference = 0.4 logMAR, Z = -1.784, P = 0.074; difference = 0.5 logMAR, Z = -1.812, P = 0.070).

Conclusion:

The findings suggest that stereoacuity values measurements taken in the natural environment state surpass those derived from the dichoptic presentation. However, the observed difference diminishes as stereopsis decreases, corresponding to an increase in induced anisometropia.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Percepción de Profundidad / Teléfono Inteligente Límite: Humans Idioma: En Revista: PeerJ Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Percepción de Profundidad / Teléfono Inteligente Límite: Humans Idioma: En Revista: PeerJ Año: 2024 Tipo del documento: Article País de afiliación: China
...