Your browser doesn't support javascript.
loading
Analytical determination of ethylenediamine impurity in tripelennamine hydrochloride by gas chromatography-mass spectrometry using phthalaldehyde as the derivatizing agent.
Kousrali, Sayyad; Kowtharapu, Leela Prasad; Mondal, Tanmoy.
Afiliación
  • Kousrali S; Department of Engineering Chemistry, Koneru Lakshmaiah Education Foundation, Aziznagar, Hyderabad, Telangana, India.
  • Kowtharapu LP; Analytical Development Department, Shenzhen DEC Pharmaceutical Co., Ltd, Shenzhen, China.
  • Mondal T; Department of Engineering Chemistry, Koneru Lakshmaiah Education Foundation, Aziznagar, Hyderabad, Telangana, India.
Biomed Chromatogr ; 38(6): e5850, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38387606
ABSTRACT
In the pharmaceutical industry, effective risk management and control strategies for potential genotoxic impurities are of paramount importance. The current study utilized GC-MS to evaluate a precise, linear, and accurate analytical method for quantifying ethylenediamine present in tripelennamine hydrochloride using phthalaldehyde as a derivatizing agent. When phthalaldehyde is sonicated for 10 min at room temperature, it reacts with ethylenediamine to form (1z,5z)-3,4-dihydrobenzo[f][1,4]diazocine. This approach minimizes matrix interference issues and resolves sample preparation difficulties encountered during ethylenediamine identification in GC-MS. In this method, helium serves as the carrier gas, while methanol acts as the diluent. The stationary phase consists of a DB-5MS column (30 m × 0.25 mm × 0.25 µm) with a flow rate of 1.5 mL/min. The retention time of (1z,5z)-3,4-dihydrobenzo[f][1,4]diazocine was determined to be 6.215 min. The method validation demonstrated limits of detection and quantification for (1z,5z)-3,4-dihydrobenzo[f][1,4]diazocine at 0.4 and 1.0 ppm, respectively, with a linearity range spanning from 1 to 30 ppm concentration with respect to the specification level. System suitability, precision, linearity, and accuracy of the current method were assessed in accordance with guidelines, yielding results deemed suitable for the intended use.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: O-Ftalaldehído / Contaminación de Medicamentos / Etilenodiaminas / Límite de Detección / Cromatografía de Gases y Espectrometría de Masas Idioma: En Revista: Biomed Chromatogr Año: 2024 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: O-Ftalaldehído / Contaminación de Medicamentos / Etilenodiaminas / Límite de Detección / Cromatografía de Gases y Espectrometría de Masas Idioma: En Revista: Biomed Chromatogr Año: 2024 Tipo del documento: Article País de afiliación: India
...