OBJECTIVE:

To investigate whether pulse-wave analysis (PWA) performed by trained evaluators facilitates detection of nonsinus rhythm. ANIMALS Same-day, high-definition oscillometry pulse-wave data and ECG results of 155 animals (144 dogs and 11 cats) were analyzed.

METHODS:

In this cross-sectional study, we enrolled 18 participants from various backgrounds, all of whom received PWA training. The ability to distinguish between sinus and nonsinus rhythms was assessed using receiver operating characteristic curve analysis. The pulse-wave datasets were divided into 5 ECG categories. Agreement between ECG diagnoses and PWA-based arrhythmia detection was evaluated using Cohen κ values, and the correlation between the academic year of veterinary students and their κ values was assessed.

RESULTS:

All cardiology researchers demonstrated satisfactory accuracy in distinguishing pathological rhythms using PWA (area under the curve, 0.704 to 0.761), with the highest accuracy in detecting atrial fibrillation (area under the curve, 0.811 to 0.845). Fair agreement with ECG categorization was achieved by all 3 cardiology researchers, 2 of 5 general practitioners, and 3 of 10 veterinary undergraduates. The veterinary undergraduates' years of study were correlated with their diagnostic performance (Spearman ρ = 0.658; P = .019). CLINICAL RELEVANCE PWA during routine noninvasive blood pressure measurement showed significant potential for the detection of pathological arrhythmias, notably atrial fibrillation. This approach yielded improved effectiveness when it was used by veterinarians with cardiology experience. Thus, introducing hands-on training courses, particularly those focused on cardiology and interactive workshops, may enable frontline veterinarians to promptly identify arrhythmias using PWA, facilitating timely ECG examinations or referrals.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Enfermedades de los Gatos / Enfermedades de los Perros / Electrocardiografía / Análisis de la Onda del Pulso Límite: Animals / Female / Humans / Male Idioma: En Revista: Am J Vet Res Año: 2024 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Enfermedades de los Gatos / Enfermedades de los Perros / Electrocardiografía / Análisis de la Onda del Pulso Límite: Animals / Female / Humans / Male Idioma: En Revista: Am J Vet Res Año: 2024 Tipo del documento: Article País de afiliación: Taiwán
...