A proof-of-principle for decontamination of transplantation kidney through UV-C exposition of the perfusate solution.
Goenaga-Mafud, L C; Vollet-Filho, J D; Costa, C; Inada, N M; Netto, A S; Kurachi, C; Bagnato, V S.
Afiliación
  • Goenaga-Mafud LC; São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil. lgoenagamafud@ifsc.usp.br.
  • Vollet-Filho JD; São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil.
  • Costa C; São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil.
  • Inada NM; São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil.
  • Netto AS; Department of Animal Science, College of Animal Science and Food Engineering, University of São Paulo, Pirassununga, SP, Brazil.
  • Kurachi C; São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil.
  • Bagnato VS; São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil.
Sci Rep ; 14(1): 5715, 2024 03 08.
Article en En | MEDLINE | ID: mdl-38459094
ABSTRACT
Kidney transplantation is a common yet highly demanding medical procedure worldwide, enhancing the quality of life for patients with chronic kidney disease. Despite its prevalence, the procedure faces a shortage of available organs, partly due to contamination by microorganisms, leading to significant organ disposal. This study proposes utilizing photonic techniques associated with organ support machines to prevent patient contamination during kidney transplantation. We implemented a decontamination system using ultraviolet-C (UV-C) irradiation on the preservation solution circulating through pigs' kidneys between harvest and implant. UV-C irradiation, alone or combined with ultrasound (US) and Ps80 detergent during ex-vivo swine organ perfusion in a Lifeport® Kidney Transporter machine, aimed to reduce microbiological load in both fluid and organ. Results show rapid fluid decontamination compared to microorganism release from the organ, with notable retention. By including Ps80 detergent at 0.5% during UV-C irradiation 3 log10 (CFU mL-1) of Staphylococcus aureus bacteria previously retained in the organ were successfully removed, indicating the technique's feasibility and effectiveness.